SAVANNAH, GA —
OSHA Inspection: UNICCO SERVICE COMPANY DBA UGL UNICCO
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of UNICCO SERVICE COMPANY DBA UGL UNICCO in 500 GULFSTREAM ROAD, BLDG. F, SAVANNAH, GA 31408 (NAICS 561210). OSHA activity number 310990023.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNICCO SERVICE COMPANY DBA UGL UNICCO
- Site address
- 500 GULFSTREAM ROAD, BLDG. F
- City
- SAVANNAH
- State
- GA
- ZIP
- 31408
- Mailing
- 500 GULFSTREAM ROAD, M/S E-02, SAVANNAH, GA 31408
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561210
- SIC code (legacy)
- 8744
- Employees
- 216
- Ownership type
- A
Citations
8 citations on file for this inspection.
5(a)(1)
- Issued
- Dec 19, 2008
- Abate by
- Dec 26, 2008
- Penalty
- Initial $5,000 · Current $5,000
General-duty citation text
P.L. 91-596 Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard(s) of a flash fire: a) Building "F" - The employer failed to ensure that employees installed components including fittings and hoses on a four bottle oxygen cart that were cleaned to a degree required for the safe operation of oxygen service equipment. Combustible material inside the manifold ignited in the presence of pure oxygen at 2000 p.s.i., resulting in the failure of the manifold and a flash fire. Among other methods, feasible and acceptable means of abatement is to use components cleaned for oxygen service in accordance with the Society of Automotive Engineers, Aerospace Recommended Practice 1176 Oxygen System and Component Cleaning and Packaging.
1910.1026 D01
- Issued
- Dec 19, 2008
- Abate by
- Jan 16, 2009
- Penalty
- Initial $2,125
0689
Recent events (2)
- — I (S)
- — Z (S) $2125.00
1910.1026 L01
- Issued
- Dec 19, 2008
- Abate by
- Jan 16, 2009
- Penalty
- Initial $2,125
0689
Recent events (2)
- — I (S)
- — Z (S) $2125.00
1910.1026 L02 IA
- Issued
- Dec 19, 2008
- Abate by
- Jan 16, 2009
0689
Recent events (2)
- — I (S)
- — Z (S)
1910.1026 L02 II
- Issued
- Dec 19, 2008
- Abate by
- Jan 16, 2009
0689
Recent events (2)
- — I (S)
- — Z (S)
1910.1200 H02 II
- Issued
- Dec 19, 2008
- Abate by
- Jan 16, 2009
0689
Recent events (2)
- — I (O)
- — Z (S)
1910.1200 H03 II
- Issued
- Dec 19, 2008
- Abate by
- Jan 16, 2009
0689
Recent events (2)
- — I (O)
- — Z (S)
1910.1200 G08
- Issued
- Dec 19, 2008
- Abate by
- Dec 26, 2008
- Penalty
- Initial $2,975
X1001900
Recent events (2)
- — I (O)
- — Z (S) $2975.00
More inspections in this industry (NAICS 561210)