MESQUITE, NV —
OSHA Inspection: SUNROC CORPORATION
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of SUNROC CORPORATION in 805 WEST RIVERSIDE, MESQUITE, NV 89024 (NAICS 327320). OSHA activity number 311014260.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SUNROC CORPORATION
- Site address
- 805 WEST RIVERSIDE
- City
- MESQUITE
- State
- NV
- ZIP
- 89024
- Mailing
- 180 NORTH 300 EAST, ST. GEORGE, UT 84770
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327320
- SIC code (legacy)
- 3273
- Employees
- 14
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
5 citations on file for this inspection.
618037501
- Issued
- Jun 25, 2007
- Abate by
- Jun 28, 2007
- Penalty
- Initial $750 · Current $563 Reduced
General-duty citation text
Nevada Revised Statute 618.375(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: a.Employees were exposed to injuries resulting from being struck by fragments of Schedule 40 PVC pipe, used to distribute up to 110 psi of compressed air, which is not recommended by the manufacturer because of heat breakdown and potential fragmentation. One feasible method, among others, would be to replace the PVC pipe with a pipe capable of withstanding compressed air distribution. Reference: PVC manufacturers data caution and warning notices which state, "Do not use compressed air or gas for pressure testing", "PVC and CPVC products are not recommended for use in compressed air or gas systems", and "the manufacturer does not recommend its PVC or CPVC products for use in air or compressed gas systems. PVC and CPVC pipe, fittings, and valves are excellent products for the transport of water and corrosive chemicals. But there are a number of other piping products that are especially designed and suited for compressed air and gases", and finally, from PW Pipe, "Do not use PVC pipe for pressurized air systems. Injury or death may result due to the catastrophic nature of pipe failure should failure occur. Rapid expansion of compressed air could propel shards of plastic through the area."h
Recent events (2)
- — I (S) $562.50
- — Z (S) $750.00
1910.243 B02
- Issued
- Jun 25, 2007
- Abate by
- Jun 28, 2007
Recent events (2)
- — I (S)
- — Z (S)
618037601
- Issued
- Jun 20, 2007
- Abate by
- Jul 20, 2007
618054001
- Issued
- Jun 20, 2007
- Abate by
- Jul 20, 2007
1910.184 E03 II
- Issued
- Jun 20, 2007
- Abate by
- Jul 20, 2007
More inspections at Sunroc Corporation
View Sunroc Corporation's full OSHA safety record →
More inspections in this industry (NAICS 327320)
More inspections in NV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 311014260.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.