ELLIJAY, GA —
OSHA Inspection: HARTLEY CONSTRUCTION COMPANY, INC.
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of HARTLEY CONSTRUCTION COMPANY, INC. in 164 DALTON STREET, ELLIJAY, GA 30539 (NAICS 236220). OSHA activity number 311034169.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HARTLEY CONSTRUCTION COMPANY, INC.
- Site address
- 164 DALTON STREET
- City
- ELLIJAY
- State
- GA
- ZIP
- 30539
- Mailing
- 1726 CLEVELAND HWY, GAINSVILLE, GA 30503
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- Yes
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- SIC code (legacy)
- 1542
- Employees
- 10
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.501 B01
- Issued
- Jan 23, 2008
- Abate by
- Feb 19, 2008
- Penalty
- Initial $4,900 · Current $3,000 Reduced
Recent events (2)
- — I (S) $3000.00
- — Z (S) $4900.00
1926.503 A01
- Issued
- Jan 23, 2008
- Abate by
- Mar 19, 2008
Recent events (2)
- — I (S)
- — Z (S)
5(a)(1)
- Issued
- Jan 23, 2008
- Abate by
- Feb 19, 2008
- Penalty
- Initial $1,050 · Current $660 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a roof truss collapse hazard when the employer failed to properly store and care for the trusses. The employer left the trusses sitting on the ground causing a deflection in the trusses. (a) On or about August 9, 2007, an employee of Hartley Construction CO., INC. was performing roof work setting and bracing up the trusses at an approximate height of 19 feet when the structure buckle and collapse killing the employee. The employer failed to properly store and care for the trusses in accordance to the manufacturer guide which suggested placing the trusses on support blocks to avoid bowing of the material. The employer stored the trusses on the ground with no support or blocks underneath causing a bow in the trusses. A feasible and acceptable method of abatement to correct this standard is to store the trusses in accordance to the BCSI guide and the truss company guide with support and blocks under the trusses, and not place the trusses directly on the ground when storing it. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $660.00
- — Z (S) $1050.00
5(a)(1)
- Issued
- Jan 23, 2008
- Abate by
- Feb 19, 2008
- Penalty
- Initial $49,000 · Current $30,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: roof truss collapse by the employer purposefully and deliberately failed to provide protection to the employees by not properly bracing up the roof trusses. The employer did not follow the BCSI guide and drawings which specifically stated the outlines or requirements in bracing/supporting the trusses. The result of the employer failing to protect the employees resulted in a fatality. (a) On or about August 9, 2007, an employee of Hartley Construction CO., INC. was performing roof work setting and bracing up the trusses at an approximate height of 19 feet when the structure buckle and collapse during the erection process killing the employee. The employer failed to properly brace up the roof trusses creating a fall hazard condition. A feasible and acceptable method of abatement to correct this standard is to install diagonal, cross bracing and permanent bracing after the first five trusses have been installed. Another feasible means would be to follow the BCSI guide and the engineering drawings to the letter. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (W) $30000.00
- — Z (W) $49000.00
More inspections at Hartley Construction Company, INC.
View Hartley Construction Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 311034169.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.