WINDER, GA —
OSHA Inspection: BOBS TIRE SERVICE, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BOBS TIRE SERVICE, INC. in 75 EAST MIDLAND AVE., WINDER, GA 30680 (NAICS 441320). OSHA activity number 311041370.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BOBS TIRE SERVICE, INC.
- Site address
- 75 EAST MIDLAND AVE.
- City
- WINDER
- State
- GA
- ZIP
- 30680
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 441320
- SIC code (legacy)
- 5531
- Employees
- 11
- Ownership type
- A
Citations
13 citations on file for this inspection.
5(a)(1)
- Issued
- Aug 29, 2008
- Abate by
- Oct 31, 2008
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being struck sharp pieces. PVC pipe was being used to transport compressed air the utilization of power tools. "Among other methods, one feasible and acceptable abatement method to correct this hazard is to:" 1. Only use material with shatter resistance properties. (Reference Plastic Pipe Institute document). 2. Follow manufacturer recommendation on application. On or about July 29, 2008 at 75 East Midland Ave., Winder, GA. a) When the employer remodeled the facility in 1994, the contractor installed Schedule 80 PVC in place the old compressed air distribution system to power pneumatic tools. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $1000.00
- — Z (S) $2000.00
1910.157 C01
- Issued
- Aug 29, 2008
- Abate by
- Sep 11, 2008
- Penalty
- Initial $800 · Current $600 Reduced
Recent events (2)
- — I (S) $600.00
- — Z (S) $800.00
1910.157 C04
- Issued
- Aug 29, 2008
- Abate by
- Sep 11, 2008
Recent events (2)
- — I (S)
- — Z (S)
1910.157 E02
- Issued
- Aug 29, 2008
- Abate by
- Oct 17, 2008
1910.157 E03
- Issued
- Aug 29, 2008
- Abate by
- Oct 17, 2008
1910.219 D01
- Issued
- Aug 29, 2008
- Abate by
- Sep 11, 2008
- Penalty
- Initial $750 · Current $600 Reduced
Recent events (2)
- — I (S) $600.00
- — Z (S) $750.00
1910.303 G01
- Issued
- Aug 29, 2008
- Abate by
- Sep 11, 2008
- Penalty
- Initial $600 · Current $400 Reduced
Recent events (2)
- — I (S) $400.00
- — Z (S) $600.00
1910.305 G02 III
- Issued
- Aug 29, 2008
- Abate by
- Sep 11, 2008
- Penalty
- Initial $600 · Current $400 Reduced
Recent events (2)
- — I (S) $400.00
- — Z (S) $600.00
1910.305 B01
- Issued
- Aug 29, 2008
- Abate by
- Sep 11, 2008
- Penalty
- Initial $600 · Current $500 Reduced
Recent events (2)
- — I (S) $500.00
- — Z (S) $600.00
1910.305 G01 IVA
- Issued
- Aug 29, 2008
- Abate by
- Sep 11, 2008
Recent events (2)
- — I (S)
- — Z (S)
1910.1200 E01
- Issued
- Aug 29, 2008
- Abate by
- Oct 17, 2008
1910.1200 G01
- Issued
- Aug 29, 2008
- Abate by
- Oct 17, 2008
Recent events (2)
- — I (O)
- — Z (O)
1910.1200 H01
- Issued
- Aug 29, 2008
- Abate by
- Oct 17, 2008
More inspections at Bobs Tire Service, INC.
View Bobs Tire Service, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 441320)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 311041370.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.