CLIFTON, NJ —
OSHA Inspection: PARKSTEIN, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PARKSTEIN, INC. in 613 ROUTE 46 EAST, CLIFTON, NJ 07013 (NAICS 423930). OSHA activity number 311052534.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PARKSTEIN, INC.
- Site address
- 613 ROUTE 46 EAST
- City
- CLIFTON
- State
- NJ
- ZIP
- 07013
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- SIC code (legacy)
- 5093
- Employees
- 24
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Jun 12, 2008
- Abate by
- Jun 17, 2008
- Penalty
- Initial $1,500 · Current $1,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being crushed when working beneath and/or alongside a wheel loader: a)Work yard behind shredder / crusher machine operator's house: Employees working on a Daewoo Mega 400-V wheel loader were exposed to the hazard of crushing injuries or death, in that tree log support stands were used to elevate this heavy equipment while employees worked underneath and/or alongside, and that the front wheels were not blocked. The stands supporting capacity was not determined and proof tested, on or about 4/10/2008. ABATEMENT NOTE: Among other methods, one feasible and acceptable method to correct this hazard is to: 1:Purchase and use commercially manufactured vehicle (automotive) support stands that incorporate the requirements of ASME Portable Automotive Lifting Devices (PALD) - 1993, section 4.1.2. As described in ASME PALD - 1993, section 4.1.2, vehicle support stands shall be capable of performing the proof load test with a load of 150of rated capacity. The ASME definition of "proof load" is a load, greater than the rated capacity, applied centrally to the lifting or attaching points of the PALD to confirm the integrity of the structure. Additionally, as described in Section 1 of the Operation & Maintenance Manual, provided through Daewoo Heavy Industries & Machinery LTD., it states the use of solid support blocking and the use of adequate equipment supports and blocking. Manual states to block wheels fore and aft to prevent any movement, and do not use hollow, cracked or unsteady, wobbling weight supports. The ASME definition of "appropriate means" is the use of any device, such as blocking, cribbing or vehicle support stands, which adequately support a vehicle off the ground by providing a stable support preventing the vehicle from tipping over of falling down to the ground.
More inspections at Parkstein, INC.
View Parkstein, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 423930)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 311052534.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.