BINGHAMTON, NY —
OSHA Inspection: BINGHAMTON CITY MOTOR POOL GARAGE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BINGHAMTON CITY MOTOR POOL GARAGE in 38 HAWLEY ST, BINGHAMTON, NY 13901 (NAICS 811111). OSHA activity number 311062848.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BINGHAMTON CITY MOTOR POOL GARAGE
- Site address
- 38 HAWLEY ST
- City
- BINGHAMTON
- State
- NY
- ZIP
- 13901
- Mailing
- 38 HAWLEY ST CITY HALL, BINGHAMTON, NY 13901
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811111
- SIC code (legacy)
- 7538
- Employees
- 2
- Ownership type
- B
Citations
14 citations on file for this inspection.
1910.23 D01 I
- Issued
- Jan 7, 2008
- Abate by
- Feb 25, 2008
1910.30 A03
- Issued
- Jan 7, 2008
- Abate by
- Feb 8, 2008
1910.132 A
- Issued
- Jan 7, 2008
- Abate by
- Jan 25, 2008
1910.303 B02
- Issued
- Jan 7, 2008
- Abate by
- Jan 25, 2008
1910.304 F05 V
- Issued
- Jan 7, 2008
- Abate by
- Jan 25, 2008
1910.305 D
- Issued
- Jan 7, 2008
- Abate by
- Jan 25, 2008
3A0001
- Issued
- Jan 7, 2008
- Abate by
- Sep 25, 2008
General-duty citation text
NYSLL Article 2, Section 27-a.3.a(1): The employer did not furnish to each of its employees, employment and a place of employment which was free from recognized hazards that are causing or were likely to cause death or serious physical harm to its employees and which will provide reasonable and adequate protection to the lives, safety or health of its employees. In applying this paragraph, fundamental distinctions between private and public employment have been recognized. a) City of Binghamton employees were exposed to the hazard of being caught under vehicles or the lift structure, or being struck by a falling vehicle, in the event of hydraulic failure of the Gilbarco hydraulic vehicle lifts (model numbers and serial numbers were not available due to age) while servicing vehicles located in the maintenance garage under City Hall. NOTE: Among other methods, one reasonable and adequate abatement method to correct this hazard is to equip the lift with a mechanical device to hold the lift in all extended positions as recommended by the American National Standards Institute and the Automobile Lift Institute in the Industry Consensus Standard ANSI/ALI B 153.1 "Safety Requirements for the Construction, Care and Use of Automobile Lifts". The device should have a strength factor of not less than three (3), based on the rated load capacity of the lift.
1910.334 A02 I
- Issued
- Jan 7, 2008
- Abate by
- Jan 25, 2008
1910.132 D01
- Issued
- Jan 7, 2008
- Abate by
- Feb 25, 2008
1910.144 A03
- Issued
- Jan 7, 2008
- Abate by
- Feb 25, 2008
1910.176 B
- Issued
- Jan 7, 2008
- Abate by
- Feb 25, 2008
1910.303 F
- Issued
- Jan 7, 2008
- Abate by
- Feb 25, 2008
1910.305 G01 III
- Issued
- Jan 7, 2008
- Abate by
- Feb 25, 2008
1910.1200 E01
- Issued
- Jan 7, 2008
- Abate by
- Feb 25, 2008
More inspections at Binghamton City Motor Pool Garage
View Binghamton City Motor Pool Garage's full OSHA safety record →
More inspections in this industry (NAICS 811111)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 311062848.