Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: FLORIDA CUSTOM COACH, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of FLORIDA CUSTOM COACH, INC. in 31017 AIRWAY RD., LEESBURG, FL 34748 (NAICS 811111). OSHA activity number 311092357.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Florida Custom Coach, INC. for free Get an email when a new federal OSHA severe-injury report for Florida Custom Coach, INC. is published. One employer, no account, unsubscribe in one click.
Site address
31017 AIRWAY RD.
City
LEESBURG
State
FL
ZIP
34748
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
SIC code (legacy)
7538
Employees
23
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 23 exposed
Issued
May 9, 2007
Abate by
Jun 26, 2007
Penalty
Initial $1,500 · Current $1,125 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and
a place of employment which were free from recognized hazards that were
causing or likely to cause death or
serious physical harm to employees in that employees were exposed to the
hazard of being struck by fragments
of plastic pipe used to transport compressed air for the operation of air
operated tools and air used for cleaning,
in the event the piping ruptures:
a. Throughout the maintenance shop, polyvinyl chloride ( PVC ) plastic
pipe was used to transport
compressed air in exposed above ground locations, for the operation of air
operated tools and air used for
cleaning, a practice not recommended by the Plastics Pipe Institute and
prohibited by ANSI/ASME B31.8-
1986, Gas Transmission and Distribution Piping Systems standard.
Among other methods one feasible and acceptable method to correct this
hazard is to replace the PVC
piping with a type that is approved for transporting compressed gases in
exposed above ground locations,
such as iron or steel piping.
Recent events (2)
  • · I (S) $1125.00
  • · Z (S) $1500.00

1910.132 D01

Other-than-serious Gravity 01 1 instance 23 exposed
Issued
May 9, 2007
Abate by
May 21, 2007
Recent events (2)
  • · I (O)
  • · Z (O)

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 311092357.