MARION, NC —
OSHA Inspection: PERFECT AIR CONTROL INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of PERFECT AIR CONTROL INC. in 896 RUTHERFORD ROAD, MARION, NC 28752 (NAICS 332999). OSHA activity number 311118392.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PERFECT AIR CONTROL INC.
- Site address
- 896 RUTHERFORD ROAD
- City
- MARION
- State
- NC
- ZIP
- 28752
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- SIC code (legacy)
- 3499
- Employees
- 117
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
10 citations on file for this inspection.
95012901
- Issued
- May 3, 2007
- Abate by
- Jun 20, 2007
- Penalty
- Initial $187 · Current $187
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish to each of his employees conditions of employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: (a) Facility, ATU line- Jib Crane with 1000 lbs capacity and one hoist was not load tested prior to initial use. REF: ANSI B30.11-1998, Chapter 11-2, Paragraph 11-2.2.2 (a)New, reinstalled, altered, repaired and modified equipment should be load tested prior to initial use as determined by a qualified person. (c)If a load test is conducted, the person conducting the load test shall prepare a written report of the load sustained during the test and the operations performed during the test. Reports shall be placed on file. NOTE: Among other methods, one feasible and acceptable method to correct this hazard is to load test the Jib Crane per the requirements of section 2.2.2 of ANSI B30-11-1998.
95012901
- Issued
- May 3, 2007
- Abate by
- Jun 20, 2007
- Penalty
- Initial $187 · Current $187
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish to each of his employees conditions of employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: (a) Facility, ATU line - Jib Crane with 1000 lbs capacity and one hoist was not inspected periodically. REF: ANSI B30.11-1998, Chapter 11-2, Paragraph 11-2.1.3 (a)Periodic inspections shall be performed at intervals defined in para. 11-2.1.1(b)(2): Visual inspection by an appointed person making records of apparent external conditions to provide the basis for a continuing evaluation, as follows: normal service, equipment in place --- annually. (c)A qualified person shall examine any deficiencies found during the inspection to determine whether conditions found constitute a hazard, require disassembly for further inspection, or require replacement. NOTE: Among other methods, one feasible and acceptable abatement method to correct this hazard is to conduct periodic inspections (annual) on the jib crane per the requirements of section 11-2.1.3 of ANSI B30-11-1998.
95012901
- Issued
- May 3, 2007
- Abate by
- Jun 20, 2007
- Penalty
- Initial $187 · Current $187
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish to each of his employees conditions of employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: (a) Facility, ATU Line - Jib Crane with 1000 lbs capacity and one hoist was not inspected frequently. REF: ANSI B30.11-1998, Chapter 11-2, Paragraph 11-2.1.2 (a)Frequent inspections shall be performed at intervals defined in para. 11-2.1.1(b)(1) and shall include observations during operation. Visual examination by the operator or other designated personnel, with records not required, as follows: normal service ---- monthly. NOTE: Among other methods, one feasible and acceptable abatement method to correct this hazard is to conduct frequent inspections (monthly) on the jib crane per the requirements of section 11-2.1.2 of ANSI B30-11-1998.
1910.147 C04 IIB
- Issued
- May 3, 2007
- Abate by
- Jun 20, 2007
- Penalty
- Initial $312 · Current $312
1910.147 C06 II
- Issued
- May 3, 2007
- Abate by
- Jun 20, 2007
1910.134 C02 I
- Issued
- May 3, 2007
- Abate by
- May 30, 2007
1910.134 C02 II
- Issued
- May 3, 2007
- Abate by
- May 30, 2007
1910.212 B
- Issued
- May 3, 2007
- Abate by
- May 30, 2007
1910.215 B09
- Issued
- May 3, 2007
- Abate by
- May 8, 2007
1910.304 F04
- Issued
- May 3, 2007
- Abate by
- May 8, 2007
More inspections at Perfect AIR Control INC.
View Perfect AIR Control INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in NC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 311118392.