Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: C S & M CABLE CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of C S & M CABLE CONSTRUCTION, INC. in 901 SOUTH NAVIGATION BOULEVARD, CORPUS CHRISTI, TX 78405 (NAICS 238210). OSHA activity number 311122006.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch C S & M Cable Construction, INC. for free Get an email when a new federal OSHA severe-injury report for C S & M Cable Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
901 SOUTH NAVIGATION BOULEVARD
City
CORPUS CHRISTI
State
TX
ZIP
78405
Mailing
5741 LEOPARD STREET, CORPUS CHRISTI, TX 78408
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
SIC code (legacy)
1731
Employees
2
Ownership type
Private (A)

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 03 1 instance 2 exposed
Issued
Sep 11, 2007
Abate by
Sep 17, 2007
Penalty
Initial $375 · Current $375
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to a struck-by hazard due to:
At this inspection site, failure to install keeper pins/wired in the ears
of crowfoot
connections of compressed air flexible rubber hoses to prevent them from
unintentional parting, at the portable Bobcat air compressor and at the
small
cooling compressor.
Among other methods, one feasible and acceptable abatement method to
correct
this hazard would be to require that keeper pins/wire be installed in each
ear of
the Crowfoot connection prior to each use per manufacturer
recommendations. 0   0   y   0                                                 L

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 311122006.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.