CORPUS CHRISTI, TX ·
OSHA Inspection: C S & M CABLE CONSTRUCTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of C S & M CABLE CONSTRUCTION, INC. in 901 SOUTH NAVIGATION BOULEVARD, CORPUS CHRISTI, TX 78405 (NAICS 238210). OSHA activity number 311122006.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- C S & M CABLE CONSTRUCTION, INC.
- Site address
- 901 SOUTH NAVIGATION BOULEVARD
- City
- CORPUS CHRISTI
- State
- TX
- ZIP
- 78405
- Mailing
- 5741 LEOPARD STREET, CORPUS CHRISTI, TX 78408
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- SIC code (legacy)
- 1731
- Employees
- 2
- Ownership type
- Private (A)
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Sep 11, 2007
- Abate by
- Sep 17, 2007
- Penalty
- Initial $375 · Current $375
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a struck-by hazard due to: At this inspection site, failure to install keeper pins/wired in the ears of crowfoot connections of compressed air flexible rubber hoses to prevent them from unintentional parting, at the portable Bobcat air compressor and at the small cooling compressor. Among other methods, one feasible and acceptable abatement method to correct this hazard would be to require that keeper pins/wire be installed in each ear of the Crowfoot connection prior to each use per manufacturer recommendations. 0 0 y 0 L