BROWNSVILLE, TX —
OSHA Inspection: TEXAS ERECTORS INC
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of TEXAS ERECTORS INC in 4335 PAREDES LINE RD, BROWNSVILLE, TX 78521 (NAICS 238120). OSHA activity number 311242804.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TEXAS ERECTORS INC
- Site address
- 4335 PAREDES LINE RD
- City
- BROWNSVILLE
- State
- TX
- ZIP
- 78521
- Mailing
- 332 MOUNTAINVIEW DR, HURST, TX 76054
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- SIC code (legacy)
- 1791
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Dec 19, 2007
- Abate by
- Dec 26, 2007
- Penalty
- Initial $2,500 · Current $1,250 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to hazards associated with collapses of precast masonry walls: On 1 August 2007, and at other times prior thereto, pipe bracing used to support tilt-up walls were installed with the following hazardous conditions: a.The pipe brace foot plates did not bear completely on the concrete floor at various points of attachment to the slab foundation or dead-man footing. b.Attachment bolts did not bear fully on the pipe brace foot plates. c.The attachment bolts and nuts were not tightened at all of the brace foot plates to prevent slippage. Among other methods of abatement, one feasible method of abatement would be to comply with the general information and instructions for use of Dayton Superior Tilt-Up Products provided by Dayton Superior in the installation of brace anchors.
Recent events (2)
- — I (S) $1250.00
- — Z (S) $2500.00
1926.20 B02
- Issued
- Dec 19, 2007
- Abate by
- Dec 26, 2007
- Penalty
- Initial $750 · Current $450 Reduced
Recent events (2)
- — I (S) $450.00
- — Z (S) $750.00
1926.351 B04
- Issued
- Dec 19, 2007
- Abate by
- Dec 26, 2007
- Penalty
- Initial $1,250 · Current $625 Reduced
Recent events (2)
- — I (S) $625.00
- — Z (S) $1250.00
1926.704 A
- Issued
- Dec 19, 2007
- Abate by
- Dec 26, 2007
- Penalty
- Initial $2,500 · Current $2,500
Recent events (2)
- — I (S) $2500.00
- — Z (S) $2500.00
More inspections at Texas Erectors INC
View Texas Erectors INC's full OSHA safety record →
More inspections in this industry (NAICS 238120)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 311242804.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.