OSHA Inspection: TEXAS ERECTORS INC

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of TEXAS ERECTORS INC in 4335 PAREDES LINE RD, BROWNSVILLE, TX 78521 (NAICS 238120). OSHA activity number 311242804.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Texas Erectors INC — free Get an email when a new federal OSHA severe-injury report for Texas Erectors INC is published. One employer, no account, unsubscribe in one click.
Establishment
TEXAS ERECTORS INC
Site address
4335 PAREDES LINE RD
City
BROWNSVILLE
State
TX
ZIP
78521
Mailing
332 MOUNTAINVIEW DR, HURST, TX 76054
Inspection type
Accident-driven (A)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
SIC code (legacy)
1791
Employees
3
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 19, 2007
Abate by
Dec 26, 2007
Penalty
Initial $2,500 · Current $1,250 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to hazards associated with collapses of precast masonry walls:
On 1 August 2007, and at other times prior thereto, pipe bracing used to
support
tilt-up walls were installed with the following hazardous conditions:
a.The pipe brace foot plates did not bear completely on the concrete floor
at various points of attachment to the slab foundation or dead-man footing.
b.Attachment bolts did not bear fully on the pipe brace foot plates.
c.The attachment bolts and nuts were not tightened at all of the brace foot
plates to prevent slippage.
Among other methods of abatement, one feasible method of abatement would be
to comply with the general information and instructions for use of Dayton
Superior Tilt-Up Products provided by Dayton Superior in the installation
of
brace anchors.
Recent events (2)
  • — I (S) $1250.00
  • — Z (S) $2500.00

1926.20 B02

Serious Gravity 01 1 instance 1 exposed
Issued
Dec 19, 2007
Abate by
Dec 26, 2007
Penalty
Initial $750 · Current $450 Reduced
Recent events (2)
  • — I (S) $450.00
  • — Z (S) $750.00

1926.351 B04

Serious Gravity 03 1 instance 1 exposed
Issued
Dec 19, 2007
Abate by
Dec 26, 2007
Penalty
Initial $1,250 · Current $625 Reduced
Recent events (2)
  • — I (S) $625.00
  • — Z (S) $1250.00

1926.704 A

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 19, 2007
Abate by
Dec 26, 2007
Penalty
Initial $2,500 · Current $2,500
Recent events (2)
  • — I (S) $2500.00
  • — Z (S) $2500.00

View Texas Erectors INC's full OSHA safety record →