ADDISON, IL ·
OSHA Inspection: ANIL PLUS CORPORATION DBA MIDAS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ANIL PLUS CORPORATION DBA MIDAS in 20W536 LAKE STREET, ADDISON, IL 60101 (NAICS 811111). OSHA activity number 311245609.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ANIL PLUS CORPORATION DBA MIDAS
- Site address
- 20W536 LAKE STREET
- City
- ADDISON
- State
- IL
- ZIP
- 60101
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811111
- SIC code (legacy)
- 7538
- Employees
- 5
- Ownership type
- A
Citations
8 citations on file for this inspection.
5(a)(1)
- Issued
- Nov 30, 2007
- Abate by
- Dec 7, 2007
General-duty citation text
Each employer shall furnish to each of his employees employment and a place of employment which are free from recognized hazards that are causing or are likely to cause death or serious physical harm to employees in that employees were exposed to possible crush hazards from falling vehicles while working with defective automotive lifts that had not been properly inspected, repaired or taken out of service. a.The "truck lift" Bay 8, was not repaired after the lift began moving up and or down on its own. b.Bay 4, Rotary lift was not inspected to determine that the lift could be lowered using only one hand lever where it is designed to be lowered using 2 hand levers. c.Removal from Service - Defective lifts were not removed from service by the employer, "Truck Lift" Bay 8 and Bay 4 Rotary lift. (ANSI/ALI-ALOIM 4.5) d.The employer did not follow the recommended inspection procedures of the lift manufacturer. (ANSI/ALI-ALOIM 2000, 5.4 - 5.5) Some feasible means of abatement would include: 1.Establish compliance with the American National Standards Institute/Automotive Lift Institute Standards ANSI/ALI-ALOIM-2000 "Standard for Automotive Lifts - Safety Requirements for Operation, Inspection and Maintenance. 2.Have lift operators conduct daily or pre-shift inspections and develop mechanisms for operators to report problems to management. 3.When problems with lifts are reported, ensure appropriate inspection. 4.Remove defective lifts from service until repaired and in safe working condition.
Recent events (2)
- · I (S)
- · Z (S)
1910.133 A01
- Issued
- Nov 30, 2007
- Abate by
- Dec 10, 2007
Recent events (2)
- · I (S)
- · Z (S)
1910.151 C
- Issued
- Nov 30, 2007
- Abate by
- Dec 17, 2007
Recent events (2)
- · I (S)
- · Z (S)
1910.303 G01 I
- Issued
- Nov 30, 2007
- Abate by
- Jan 2, 2008
Recent events (2)
- · I (S)
- · Z (S)
1910.1200 E01
- Issued
- Nov 30, 2007
- Abate by
- Mar 3, 2008
- Penalty
- Initial $600 · Current $420 Reduced
Recent events (2)
- · I (S) $420.00
- · Z (S) $600.00
1910.1200 E01 I
- Issued
- Nov 30, 2007
- Abate by
- Mar 3, 2008
Recent events (2)
- · I (S)
- · Z (S)
1910.1200 G01
- Issued
- Nov 30, 2007
- Abate by
- Mar 3, 2008
Recent events (2)
- · I (S)
- · Z (S)
1910.1200 H01
- Issued
- Nov 30, 2007
- Abate by
- Mar 3, 2008
Recent events (2)
- · I (S)
- · Z (S)
More inspections in this industry (NAICS 811111)
More inspections in IL
Source