BENSALEM, PA ·
OSHA Inspection: MARK PATTON, INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MARK PATTON, INC in 4136 HULMEVILLE RD., BENSALEM, PA 19020 (NAICS 238130). OSHA activity number 311269369.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MARK PATTON, INC
- Site address
- 4136 HULMEVILLE RD.
- City
- BENSALEM
- State
- PA
- ZIP
- 19020
- Mailing
- 62 HAWTHORNE LANE, LEVITTOWN, PA 19055
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- SIC code (legacy)
- 1751
- Employees
- 5
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 14, 2008
- Abate by
- Oct 29, 2008
- Penalty
- Initial $1,500 · Current $1,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to caught between/struck by and fall hazards and resulting blunt force trauma from roof truss collapse: a) Construction site, St. Gregorios Macankara Orthodox Church - On or about July 18, 2008 Employees were installing sheathing scissor trusses spanning 64 feet did not install adequate temporary bracing allowing 53 of the 76 trusses to collapse. Among other methods, one feasible and acceptable abatement method would be to follow recommendations of the Truss Plate Institute and Wood Truss Council of America BCSI-B2 Summary sheet Guide for Installation and Temporary Bracing, which was provided with the trusses by the manufacturer. These recommendations would include but not be limited to the following: 1. Consult a Professional Engineer for installation and temporary bracing of trusses over 60 feet as specified in the first warning paragraph. 2. Install sheathing immediately as stated in the first paragraph regarding maximum spacing for top chord temporary lateral bracing. 3. Install TCTLR maximum 4 feet O.C. as specified on pg. 1 4. Install temporary bracing throughout, as specified in step 5 thru 8. 5. Pre assemble trusses for installation as documented in BCSI-B11. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
1926.501 B04
- Issued
- Oct 14, 2008
- Abate by
- Oct 17, 2008
- Penalty
- Initial $375 · Current $375
1926.501 B14
- Issued
- Oct 14, 2008
- Abate by
- Oct 17, 2008
More inspections in this industry (NAICS 238130)