Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: MARK PATTON, INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MARK PATTON, INC in 4136 HULMEVILLE RD., BENSALEM, PA 19020 (NAICS 238130). OSHA activity number 311269369.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mark Patton, INC for free Get an email when a new federal OSHA severe-injury report for Mark Patton, INC is published. One employer, no account, unsubscribe in one click.
Establishment
MARK PATTON, INC
Site address
4136 HULMEVILLE RD.
City
BENSALEM
State
PA
ZIP
19020
Mailing
62 HAWTHORNE LANE, LEVITTOWN, PA 19055
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
SIC code (legacy)
1751
Employees
5
Ownership type
Private (A)

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 5 exposed
Issued
Oct 14, 2008
Abate by
Oct 29, 2008
Penalty
Initial $1,500 · Current $1,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to caught between/struck by and fall hazards and resulting
blunt force trauma from
roof truss collapse:
a) Construction site, St. Gregorios Macankara Orthodox Church - On or about
July 18, 2008 Employees were installing sheathing scissor trusses spanning
64
feet did not install adequate temporary bracing allowing 53 of the 76
trusses to
collapse.
Among other methods, one feasible and acceptable abatement method would be
to follow
recommendations of the Truss Plate Institute and Wood Truss Council of
America BCSI-B2
Summary sheet Guide for Installation and Temporary Bracing, which was
provided with the
trusses by the manufacturer.
These recommendations would include but not be limited to the following:
1. Consult a Professional Engineer for installation and temporary bracing
of
trusses over 60 feet as specified in the first warning paragraph.
2. Install sheathing immediately as stated in the first paragraph regarding
maximum spacing for top chord temporary lateral bracing.
3. Install TCTLR maximum 4 feet O.C. as specified on pg. 1
4. Install temporary bracing throughout, as specified in step 5 thru 8.
5. Pre assemble trusses for installation as documented in BCSI-B11.
Abatement certification required within 10 days after abatement date.  The
certification shall
include a statement that abatement is complete, date and method of
abatement, and states
employees and their representatives were informed of this abatement.

1926.501 B04

Serious Gravity 03 1 instance 6 exposed
Issued
Oct 14, 2008
Abate by
Oct 17, 2008
Penalty
Initial $375 · Current $375

1926.501 B14

Serious Gravity 03 1 instance 6 exposed
Issued
Oct 14, 2008
Abate by
Oct 17, 2008

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 311269369.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.