Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CASSO-SOLAR CORP.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of CASSO-SOLAR CORP. in 230 RTE. 202, POMONA, NY 10970 (NAICS 333994). OSHA activity number 311283121.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Casso-Solar Corp. — free Get an email when a new federal OSHA severe-injury report for Casso-Solar Corp. is published. One employer, no account, unsubscribe in one click.
Establishment
CASSO-SOLAR CORP.
Site address
230 RTE. 202
City
POMONA
State
NY
ZIP
10970
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333994
SIC code (legacy)
3567
Employees
23
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 03 2 instances 4 exposed
Issued
Jul 30, 2008
Abate by
Sep 4, 2008
Penalty
Initial $750 · Current $750
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the hazard of being struck by falling loads and/or falling
hoist parts:
a)Shop Area:  A CM Valustar underhung hoist was being used to lift metal
tubes
and metal angles.  The hoist components, including, but not limited to,
operating
mechanisms, limit devices, braking systems, hooks, etc. had not been
subject to
regular inspections; on or about 7/16/08.
b)Shop Area:  A underhung hoist was being used to lift oven control
cabinets and
the hoist components had not been subject to regular inspections; on or
about
7/16/08.
One feasible and acceptable abatement method, among others, to correct
this hazard is to
conduct the frequent and periodic inspection requirements referenced in
ANSI/ASME B30.16-
2003.
NOTE: The employer is required to submit abatement certification for this
item in
accordance with 29 CFR 1903.19.ce

1910.133 A01

Serious Gravity 01 1 instance 1 exposed
Issued
Jul 30, 2008
Abate by
Aug 7, 2008
Penalty
Initial $450 · Current $450

1910.215 A01

Serious Gravity 02 1 instance 2 exposed
Issued
Jul 30, 2008
Abate by
Sep 4, 2008
Penalty
Initial $600 · Current $600

1910.215 A04

Serious Gravity 02 1 instance 2 exposed
Issued
Jul 30, 2008
Abate by
Sep 4, 2008

1910.134 F02

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Jul 30, 2008
Abate by
Aug 7, 2008

View Casso-Solar Corp.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 311283121.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.