NEW ROCHELLE, NY —
OSHA Inspection: BEL-AQUA POOL SUPPLY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BEL-AQUA POOL SUPPLY, INC. in 20 COMMERCE DRIVE, NEW ROCHELLE, NY 10801 (NAICS 423910). OSHA activity number 311285399.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BEL-AQUA POOL SUPPLY, INC.
- Site address
- 20 COMMERCE DRIVE
- City
- NEW ROCHELLE
- State
- NY
- ZIP
- 10801
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423910
- SIC code (legacy)
- 5091
- Employees
- 45
- Ownership type
- A
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 3, 2008
- Abate by
- Oct 8, 2008
- Penalty
- Initial $875 · Current $875
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employmnent and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being crushed by the hydraulic arm of the compactor: Location: Establishment, Low Bay Area a) Employer did not follow a program of periodic and regular inspections of all stationary compactors to ensure that all parts, component equipment, and safeguards are in safe operating condition. This inspection program did not include records of inspections which would have resulted in observing the compactor door opened and the compactor parts moving at the point of operation due to the door not being interlocked, on or about 08/25/08. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE METHOD TO CORRECT THIS HAZARD IS TO FOLLOW THE ANSI Z245.2-2004, WHICH STATES THAT THE OWNER/EMPLOYER SHALL BE RESPONSIBLE FOR: "ESTABLISHING AND FOLLOWING A PROGRAM OF PERIODIC AND REGULAR INSPECTIONS OF ALL STATIONARY COMPACTORS TO ENSURE THAT ALL PARTS, COMPONENT EQUIPMENT, AND SAFEGUARDS ARE IN SAFE OPERATING CONDITION, AND ADJUSTED, IN ACCORDANCE WITH THE MANUFACTURER'S PROCEDURES. THIS SHALL INCLUDE KEEPING ALL MALFUNCTION REPORTS AND RECORDS OF INSPECTIONS AND MAINTENANCE WORK PERFORMED." "ENSURING THAT ALL REQUIRED SAFETY FEATURES ARE OPERATIONAL AND FUNCTIONING, AND REPAIRING, PRIOR TO PLACING INTO SERVICE, ANY REPORTED MALFUNCTION OR DEFECT THATY AFFECTS THE SAFE OPERATION OF THE STATIONARY COMPACTOR". NOTE: Because abatement of this violation is already documented in the inspection case file, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
1910.145 C02 I
- Issued
- Oct 3, 2008
- Abate by
- Oct 14, 2008
- Penalty
- Initial $525 · Current $525
1910.212 A01
- Issued
- Oct 3, 2008
- Abate by
- Oct 8, 2008
- Penalty
- Initial $875 · Current $875
1910.305 B02
- Issued
- Oct 3, 2008
- Abate by
- Oct 8, 2008
More inspections at Bel-Aqua Pool Supply, INC.
View Bel-Aqua Pool Supply, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 423910)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 311285399.