BIG SPRING, TX ·
OSHA Inspection: WEST TEXAS ENERGY SERVICES, LLC
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of WEST TEXAS ENERGY SERVICES, LLC in RIG 2, WILDHOUSE 21 #5, BIG SPRING, TX 79721 (NAICS 213111). OSHA activity number 311307573.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WEST TEXAS ENERGY SERVICES, LLC
- Site address
- RIG 2, WILDHOUSE 21 #5
- City
- BIG SPRING
- State
- TX
- ZIP
- 79721
- Mailing
- PO BOX 1870, BIG SPRING, TX 79721
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- Yes
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213111
- SIC code (legacy)
- 1381
- Employees
- 17
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
8 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 25, 2007
- Abate by
- Nov 21, 2007
- Penalty
- Initial $1,125 · Current $675 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the condition(s) listed below: West Texas Energy Service, LLC., Rig 2, Wildhorse "21" #5, Howard County, TX. For the period of time up to and including 09/17/07, an auxiliary means of escape, such as a Geronimo line, was not installed prior to personnel working in the derrick. API Recommended Practice 54, Third Edition, April 1999, titled "Recommended Practice for Occupational Safety for Oil and Gas Drilling and Servicing Operations", states in Section 6, Paragraph 6.10.1, "On all land rigs, the derrick or mast shall have an auxiliary means of escape installed prior to personnel working in the derrick." Among other methods, one feasible and acceptable abatement method to correct this hazard is to ensure an auxiliary means of escape, such as a geronimo line, is installed prior to personnel working in the derrick.
Recent events (2)
- · I (S) $675.00
- · Z (S) $1125.00
5(a)(1)
- Issued
- Oct 25, 2007
- Abate by
- Jan 21, 2008
- Penalty
- Initial $1,125 · Current $675 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the condition(s) listed below: West Texas Energy Service, LLC., Rig 2, Wildhorse "21" #5, Howard County, TX. For the period of time up to and including 09/17/07, employees were exposed to struck-by hazards due to the lack of anti-two blocking or some other device that would positively prevent the traveling block from striking the crown block. API Recommended Practice 54, Third Edition, April 1999, titled "Recommended Practice for Occupational Safety for Oil and Gas Drilling and Servicing Operations", states in Section 6, Paragraph 6.3.2, "Well operations involving the rig shall not be commenced until the rig is rigged up in a safe manner." Among other methods, one feasible and acceptable abatement method to correct this hazard is to equip the drilling rig(s) with anti-two blocking, crown-o-matics or other positive devices that will prevent the traveling block from making contact with the crown block.
Recent events (2)
- · I (S) $675.00
- · Z (S) $1125.00
1910.23 A05
- Issued
- Oct 25, 2007
- Abate by
- Nov 21, 2007
- Penalty
- Initial $675 · Current $405 Reduced
Recent events (2)
- · I (S) $405.00
- · Z (S) $675.00
1910.23 A08
- Issued
- Oct 25, 2007
- Abate by
- Nov 21, 2007
1910.23 A07
- Issued
- Oct 25, 2007
- Abate by
- Oct 30, 2007
- Penalty
- Initial $1,125 · Current $675 Reduced
Recent events (2)
- · I (S) $675.00
- · Z (S) $1125.00
1910.23 D01 III
- Issued
- Oct 25, 2007
- Abate by
- Nov 21, 2007
- Penalty
- Initial $675 · Current $405 Reduced
Recent events (2)
- · I (S) $405.00
- · Z (S) $675.00
1910.151 C
- Issued
- Oct 25, 2007
- Abate by
- Nov 21, 2007
- Penalty
- Initial $675 · Current $405 Reduced
Recent events (2)
- · I (S) $405.00
- · Z (S) $675.00
1910.212 A01
- Issued
- Oct 25, 2007
- Abate by
- Nov 21, 2007
- Penalty
- Initial $675 · Current $405 Reduced
Recent events (2)
- · I (S) $405.00
- · Z (S) $675.00
More inspections at West Texas Energy Services, LLC
View West Texas Energy Services, LLC's full OSHA safety record →
More inspections in this industry (NAICS 213111)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 311307573.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.