Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: DELL RAPIDS FORD

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DELL RAPIDS FORD in 308 WEST THIRD STREET, DELL RAPIDS, SD 57022 (NAICS 441110). OSHA activity number 311319743.

Watch Dell Rapids Ford — free Get an email when a new federal OSHA severe-injury report for Dell Rapids Ford is published. One employer, no account, unsubscribe in one click.
Establishment
DELL RAPIDS FORD
Site address
308 WEST THIRD STREET
City
DELL RAPIDS
State
SD
ZIP
57022
Mailing
308 WEST THIRD STREET, DELL RAPIDS, SD 57022
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441110
SIC code (legacy)
5511
Employees
6
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 03 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1750.00 · Current $438.00 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to crushing and/or struck-by hazards:
(a) Service bay area, for employees operating the Rotary and other brand
two-post and
four-post automotive lifts where the employer had not developed and
implemented an
annual lift inspection program.
(b) Service bay area, for employees operating the Rotary and other brand
two-post and
four-post automotive lifts where the employer had not developed and
implemented an
annual training program.
Abatement Note:
Among other methods, one feasible and acceptable method of abatement would
be
to
follow the requirements of ANSI/ALI ALOIM and/or ANSI B153.1 which
includes,
among other requirements, the following:
1.Institute a preventive maintenance program according to the
manufacturer's
specifications.
2.Provide training to employees on proper use and care of the lifts.
3.Ensure all lifts are rated and marked with their load capacity.
4.Schedule and complete all periodic and annual inspections.
Abatement Note:  Abatement certification is required for this item (see
enclosed "Sample
Abatement Certification Letter").tion
Recent events (2)
  • — I (S) $437.50
  • — Z (S) $1750.00

AEROTEK

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 311319743.