HORMIGUEROS, PR ·
OSHA Inspection: TRAN, QUANG THONG DBA CHINA NAILS
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TRAN, QUANG THONG DBA CHINA NAILS in CARR 2 PLAZA MONSERRATE #1, HORMIGUEROS, PR 00660 (NAICS 812113). OSHA activity number 311390371.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TRAN, QUANG THONG DBA CHINA NAILS
- Site address
- CARR 2 PLAZA MONSERRATE #1
- City
- HORMIGUEROS
- State
- PR
- ZIP
- 00660
- Mailing
- PO BOX 127, HORMIGUEROS, PR 00660
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 812113
- SIC code (legacy)
- 7231
- Employees
- 11
- Ownership type
- A
Citations
5 citations on file for this inspection.
6A0001
- Issued
- Apr 6, 2010
- Abate by
- Apr 24, 2010
- Penalty
- Initial $450
General-duty citation text
Section 6(a) of the Puerto Rico Occupational Safety and Health Act: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or physical harm to employees in that employees were exposed to: Seccion 6(a) de la Ley de Seguridad y Salud en el Trabajo de Puerto Rico: El patrono no proveyo empleo y un sitio de empleo libre de riesgos reconocidos que esten causando o que puedan causar muerte o dano fisico a los empleados, por cuanto empleados estaban expuestos a: a)Workplace - nail designer employee handled the acrylic nail product (CND Retention + Sculpting Liquid ). The employer kept the required ventilation system turned off during working hours permiting an increasing concentration of a the explosive component Ethyl Methacrylate. Hazard: respiratory tract irritation, allergies, headache, and explosion. Among other methods, one feasible and acceptable method to correct this hazard is: to provide a ventilation system at the point of use (working tables) and keeping the ventilation system on until all the contaminant vapors are removed from the workplace. a)Lugar de trabajo - empleado de diseno de una manejaban el producto para unas acrilicas (CND Retention + Sculpting liquid). El patrono mantenia el sistema de ventilacion requerido apagado permitiendo un incremento de la concentracion del componente altamente explosivo Ethyl Methacrylate. Riesgo: irritacion del tracto respiratorio, alergias, dolor de cabeza y explosion. Entre otros metodos de correccion, un metodo factible y aceptable para corregir este riesgo es el siguiente: Proveer un sistema de ventilacion en el punto de uso (mesas de trabajo) y mantener el sistema de ventilacion prendido hasta que todos los vapores contaminantes hallan sido removidos del area de trabajo."
Recent events (2)
- · I (O)
- · Z (S) $450.00
1903.2 A01
- Issued
- Apr 6, 2010
- Abate by
- Apr 11, 2010
1910.1200 E01
- Issued
- Apr 6, 2010
- Abate by
- Apr 24, 2010
1910.1200 G08
- Issued
- Apr 6, 2010
- Abate by
- Apr 14, 2010
1910.1200 H01
- Issued
- Apr 6, 2010
- Abate by
- Apr 24, 2010
More inspections in this industry (NAICS 812113)