CONCORD, NC —
OSHA Inspection: MASTER FAB, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MASTER FAB, INC. in 1745 DERITA RD., CONCORD, NC 28027 (NAICS 238120). OSHA activity number 311502975.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MASTER FAB, INC.
- Site address
- 1745 DERITA RD.
- City
- CONCORD
- State
- NC
- ZIP
- 28027
- Mailing
- 4304 OLD LINCOLNTON HWY, CROUSE, NC 28033
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- SIC code (legacy)
- 1791
- Employees
- 7
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
1 citation on file for this inspection.
95012901
- Issued
- Dec 7, 2007
- Abate by
- Dec 12, 2007
- Penalty
- Initial $1,400 · Current $1,400
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish to each of his employees conditions of employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck by overturning and/or falling objects hazards: a)jobsite, North side of building, for the National Crane mobile crane being used to lift a Miller Trailblazer welder/generator to the roof of a building under construction. On 10/18/07, the front outrigger on the side of the crane nearest the building and the two rear outriggers were not lowered in place causing the mobile crane to overturn and the crane boom to crash into the building's masonry wall throwing the welder/generator onto the metal roof decking, damaging the roof. Among other methods, one feasible and acceptable abatement method to correct this hazard was to have all outriggers lowered, set, and the crane balanced prior to hoisting a load. Ref: Safety Code for Cranes, Derricks, Hosits, Jacks, and Slings, USA Standard B30.5 - 1968, Section 5-3.2.3 (i).
More inspections at Master FAB, INC.
View Master FAB, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238120)
More inspections in NC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 311502975.