CLEVELAND, OH —
OSHA Inspection: ROYAL POWDER CORPORATION
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of ROYAL POWDER CORPORATION in 4650 W. 160TH ST., CLEVELAND, OH 44135 (NAICS 325510). OSHA activity number 311504880.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ROYAL POWDER CORPORATION
- Site address
- 4650 W. 160TH ST.
- City
- CLEVELAND
- State
- OH
- ZIP
- 44135
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325510
- SIC code (legacy)
- 2851
- Employees
- 7
- Ownership type
- A
Citations
17 citations on file for this inspection.
5(a)(1)
- Issued
- Nov 17, 2008
- Abate by
- Jan 20, 2009
- Penalty
- Initial $750 · Current $450 Reduced
General-duty citation text
5(a)(1): Section 5 (a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm, including severe burns, to employees in that employees were exposed to dust explosion, deflagration or other fire hazards from dust collectors that lacked explosion protection systems: a)The dust collector in the Mixing Department did not have an explosion protection system, and was installed inside the building; b)The dust collector in the Extruder Department did not have an explosion protection system, and was installed inside the building; c)The dust collector installed outside the rear of the building which exhausts the cyclone at the grinder was not provided with an isolation device to prevent dust explosions from traveling back into the building. Among other methods, a feasible abatement method to correct this hazard is: (1) Relocate indoor dust collectors to outside the facility or install engineering controls such as suppression, inerting, and/or explosion venting to the outside; and (2) Install isolation devices to prevent explosions back through ductwork. Install per requirements of the National Fire Protection Association's (NFPA) Standard 654, "Standard for the prevention of Fire and Dust Explosions from the Manufacturing, Processing and Handling of Combustible Solids" and NFPA 69, "Standard on Explosion Prevention Systems" and NFPA 68, "Guide for Venting Deflagrations".
Recent events (4)
- — I $2400.00
- — Z $6000.00
- — I (S) $450.00
1910.29 A04 III
- Issued
- Nov 17, 2008
- Abate by
- Dec 5, 2008
- Penalty
- Initial $450 · Current $270 Reduced
Recent events (2)
- — I (S) $270.00
- — Z (S) $450.00
1910.107 C02
- Issued
- Nov 17, 2008
- Abate by
- Dec 16, 2008
- Penalty
- Initial $450 · Current $270 Reduced
Recent events (4)
- — I $1080.00
- — Z $2700.00
- — I (S) $270.00
1910.132 A
- Issued
- Nov 17, 2008
- Abate by
- Dec 9, 2008
- Penalty
- Initial $1,500 · Current $900 Reduced
Recent events (2)
- — I (S) $900.00
- — Z (S) $1500.00
1910.132 D01
- Issued
- Nov 17, 2008
- Abate by
- Dec 9, 2008
Recent events (2)
- — I (S)
- — Z (S)
1910.305 B02
- Issued
- Nov 17, 2008
- Abate by
- Dec 9, 2008
Recent events (2)
- — I (S)
- — Z (S)
1910.147 C04 I
- Issued
- Nov 17, 2008
- Abate by
- Jan 2, 2009
- Penalty
- Initial $750 · Current $450 Reduced
Recent events (2)
- — I (S) $450.00
- — Z (S) $750.00
1910.212 A04
- Issued
- Nov 17, 2008
- Abate by
- Jan 2, 2009
- Penalty
- Initial $750 · Current $450 Reduced
Recent events (2)
- — I (S) $450.00
- — Z (S) $750.00
1910.219 D01
- Issued
- Nov 17, 2008
- Abate by
- Nov 25, 2008
- Penalty
- Initial $450 · Current $270 Reduced
Recent events (2)
- — I (S) $270.00
- — Z (S) $450.00
1910.242 B
- Issued
- Nov 17, 2008
- Abate by
- Dec 16, 2008
- Penalty
- Initial $600 · Current $360 Reduced
Recent events (2)
- — I (S) $360.00
- — Z (S) $600.00
1910.1200 E01
- Issued
- Nov 17, 2008
- Abate by
- Dec 5, 2008
- Penalty
- Initial $600 · Current $360 Reduced
Recent events (2)
- — I (S) $360.00
- — Z (S) $600.00
1910.1200 H02 II
- Issued
- Nov 17, 2008
- Abate by
- Dec 16, 2008
Recent events (2)
- — I (S)
- — Z (S)
1910.26 C03 III
- Issued
- Nov 17, 2008
- Abate by
- Jan 2, 2009
Recent events (2)
- — I (O)
- — Z (O)
1910.134 C02 I
- Issued
- Nov 17, 2008
- Abate by
- Dec 8, 2008
9135T405
Recent events (2)
- — I (O)
- — Z (O)
1910.178 L06
- Issued
- Nov 17, 2008
- Abate by
- Jan 2, 2009
Recent events (2)
- — I (O)
- — Z (O)
1910.303 B02
- Issued
- Nov 17, 2008
- Abate by
- Nov 25, 2008
1910.305 G02 III
- Issued
- Nov 17, 2008
- Abate by
- Nov 30, 2008
More inspections at Royal Powder Corporation