OSHA Inspection: CITADEL DESIGN BUILD INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CITADEL DESIGN BUILD INC. in NORTH HWY 95, BONNERS FERRY, ID 83805 (NAICS 238130). OSHA activity number 311579809.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Citadel Design Build INC. for free Get an email when a new federal OSHA severe-injury report for Citadel Design Build INC. is published. One employer, no account, unsubscribe in one click.
Site address
NORTH HWY 95
City
BONNERS FERRY
State
ID
ZIP
83805
Mailing
PO BOX 261, BONNERS FERRY, ID 83805
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
SIC code (legacy)
1751
Employees
4
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 03 5 instances 4 exposed
Issued
Feb 9, 2009
Abate by
Feb 13, 2009
Penalty
Initial $750 · Current $375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not
furnish employment and a place of employment which was free from
recognized hazards that
were likely to cause death or serious physical harm to the employees in
that employees were
exposed to struck by/caught between hazards from roof truss collapse
during installation:
(a)On or about December 12, 2008, and at times prior thereto, employees had
installed 21 common trusses (bottom chord span of 60 feet) without top
chord
diagonal bracing.
(b)On or about December 12, 2008, and at times prior thereto, employees had
installed 21 common trusses (bottom chord span of 60 feet) without bottom
chord (horizontal) diagonal bracing.
(c)On or about December 12, 2008, and at times prior thereto, employees had
installed 21 common trusses (bottom chord span of 60 feet) without
sufficient
top chord lateral bracing. Only one row of metal restraints had been
installed
on each top chord (sloping side).
(d)On or about December 12, 2008, and at times prior thereto, employees had
installed 21 common trusses (bottom chord span of 60 feet) without
sufficient
bottom chord (horizontal) lateral bracing.  Only one lateral brace had been
placed near the centerline.
(e)On or about December 12, 2008, and at times prior thereto, employees had
installed 21 common trusses (bottom chord span of 60 feet) without web
diagonal bracing.
NOTE: Feasible and acceptable abatement methods to correct this hazard
would be to follow
the Building Component Safety Information BCSI B-1 - Guide for Handling,
Installing and
Bracing of Metal Plate Connected Wood Trusses, and BCSI B-2 - Truss
Installation &
Temporary Restraint/Bracing, issued by the Wood Truss Council of America
and the Truss
Plate Institute.  Bracing may be installed as a permanent part of the
structure and/or installed
temporarily until structural sheathing has been installed.
NOTE: Abatement Certification IS required for this item.
Recent events (2)
  • · I (S) $375.00
  • · Z (S) $750.00

5(a)(1)

Deleted Serious Gravity 03 1 instance 4 exposed
Issued
Feb 9, 2009
Abate by
Feb 13, 2009
Penalty
Initial $750 · Current $750
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not
furnish employment and a place of employment which was  free from
recognized hazards
that were likely to cause death or serious physical harm to the employees
in that employees
were exposed to struck- by hazards from roof truss damage and failure:
(a)On or about December 12, 2008, and at times prior thereto, trusses were
exposed to point loading and damage when employees were placing 60 foot
span trusses using a single pick-point at the peak.
NOTE: Feasible and acceptable methods to correct this hazard would be to
follow the
Building Component Safety Information BCSI B-1 Summary Sheet - Guide for
Handling,
Installing and Bracing of Metal Plate Connected Wood Trusses, issued by
the Wood Truss
Council of America and the Truss Plate Institute.  Single trusses between
30 feet and 60 feet
must use a spreader bar with lines that slope inward or "toe-in" to
prevent the truss from
buckling.
NOTE: Abatement Certification IS required for this item.
Recent events (2)
  • · I (S) $750.00
  • · Z (S) $750.00

1926.100 A

Other-than-serious Gravity 02 1 instance 1 exposed
Issued
Feb 9, 2009
Abate by
Feb 12, 2009
Penalty
Initial $600 · Current $250 Reduced
Recent events (2)
  • · I (O) $250.00
  • · Z (S) $600.00

1926.501 B13

Serious Gravity 03 1 instance 1 exposed
Issued
Feb 9, 2009
Abate by
Feb 12, 2009
Penalty
Initial $750 · Current $375 Reduced
Recent events (2)
  • · I (S) $375.00
  • · Z (S) $750.00