LAS VEGAS, NV —
OSHA Inspection: EXECUTIVE WINDOW CLEANING & HIGH REACH SPECIALISTS
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of EXECUTIVE WINDOW CLEANING & HIGH REACH SPECIALISTS in 4575 SOUTH DEAN MARTIN DRIVE, LAS VEGAS, NV 89109 (NAICS 561790). OSHA activity number 311641328.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EXECUTIVE WINDOW CLEANING & HIGH REACH SPECIALISTS
- Site address
- 4575 SOUTH DEAN MARTIN DRIVE
- City
- LAS VEGAS
- State
- NV
- ZIP
- 89109
- Mailing
- 6269 INDUSTRIAL ROAD, LAS VEGAS, NV 89118
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561790
- SIC code (legacy)
- 7349
- Employees
- 10
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
3 citations on file for this inspection.
618037501
- Issued
- May 19, 2008
- Abate by
- Jun 21, 2008
- Penalty
- Initial $375 · Current $225 Reduced
General-duty citation text
Nevada Revised Statute 618.375(1): The employer failed to furnish employment and a place of employment which was free from recognized hazards that were causing or were likely to cause death or serious physical harm to his employees: The employer failed to ensure that the place of employment was free from recognized hazards, as follows: a.Panorama Tower II. 4575 S. Dean Martin Drive, Las Vegas, NV. During window cleaning operations, two employees using a "Rope Descent Systems (RDS)" were not properly trained. Employees interviewed thought the anchorage and seatboard in use were proper but they were not. Employees descended from the top of a 35 story building that was more than 300 feet in elevation. Reference: ANSI/IWCA I-14.1-2001; "Window Cleaning Safety", Section 5.7.2; Rope Descent Systems (RDS). Employees shall be trained in the use and care of rope descent systems before they are permitted to use such equipment. Training shall include but not limited to understanding the manufacturer's instructions, inspection of components, accepted rigging practices, identifying anchorages, descending, fall arrest requirements, rescue consideration and a full understanding of safe working conditions considering as a minimum, correct rigging, rope use, inspection and care the effects of wind on suspended operations. One feasible means of abatement is to follow the requirements of ANSI/IWCA I-14.1- 2001; "Window Cleaning Safety".
Recent events (2)
- — I (S) $225.00
- — Z (S) $375.00
618037501
- Issued
- May 19, 2008
- Abate by
- May 22, 2008
- Penalty
- Initial $375 · Current $225 Reduced
General-duty citation text
Nevada Revised Statute 618.375(1): The employer failed to furnish employment and a place of employment which was free from recognized hazards that were causing or were likely to cause death or serious physical harm to his employees: The employer failed to ensure that the place of employment was free from recognized hazards, as follows: a.Panorama Tower II. 4575 S. Dean Martin Drive, Las Vegas, NV. During window cleaning operations, an employee was using a "Rope Descent System (RDS)"to access the windows. The seatboard of one of the RDS systems was wrapped with duct tape. When the duct tape was removed, the seatboard was deteriorated and modified. The employee descended from the top of a 35 story building that was more than 300 feet in elevation. Reference: ANSI/IWCA I-14.1-2001; "Window Cleaning Safety", Section 3.2; Equipment Design Requirements. All equipment shall be engineered, designed and approved by the manufacturer for use in window cleaning conforming with the requirements of Part B of this Standard. Alterations to the characteristics of a unit's design or capacity to safely support the equipment and its operators shall be prohibited unless specifically approved in writing by its original manufacturer or a registered professional engineer. Section 14.3(d); Any finish or covering on the wood product shall be transparent. One feasible means of abatement is to follow the requirements of ANSI/IWCA I-14.1- 2001; "Window Cleaning Safety".
Recent events (2)
- — I (S) $225.00
- — Z (S) $375.00
618037501
- Issued
- May 19, 2008
- Abate by
- Jun 21, 2008
- Penalty
- Initial $375 · Current $225 Reduced
General-duty citation text
Nevada Revised Statute 618.375(1): The employer failed to furnish employment and a place of employment which was free from recognized hazards that were causing or were likely to cause death or serious physical harm to his employees: The employer failed to ensure that the place of employment was free from recognized hazards, as follows: a.Panorama Tower II. 4575 S. Dean Martin Drive, Las Vegas, NV. The "Rope Descent Systems (RDS)" and independent lifeline anchorage points were not certified under the supervision of a registered professional engineer. They used a rope that was wrapped around a steel beam instead of approved anchorages and snap hooks. Employees descended from the top of a 35 story building that was more than 300 feet in elevation. Reference: ANSI/IWCA I-14.1-2001; "Window Cleaning Safety", Section 3.9; Anchorages. Building owners and window cleaning contractors shall not allow suspended work to be performed unless it has been determined that the building has provided , identified and certified anchorages complying with section 9 or 10 for: independent safety lines; tie-backs; parapet clamps and cornice hooks; primary support anchorages for powered and manual boatswain's chair; primary support for rope descent systems; horizontal (rope) lines or lifelines; and whatever else required. Section 9.1.8 Anchorages and Fall Protection. Each anchorage shall be identified in the work plan in accordance with section 1.7. One feasible means of abatement is to follow the requirements of ANSI/IWCA I-14.1- 2001; "Window Cleaning Safety".
Recent events (2)
- — I (S) $225.00
- — Z (S) $375.00
More inspections in this industry (NAICS 561790)
More inspections in NV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 311641328.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.