HURRICANE, WV —
OSHA Inspection: DYNAMIC CONSTRUCTION LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DYNAMIC CONSTRUCTION LLC in MIDLAND CROSSING APARTMENTS 165 MIDLAND TRAIL, HURRICANE, WV 25526 (NAICS 236116). OSHA activity number 311681183.
Where did this inspection happen?
- Establishment
- DYNAMIC CONSTRUCTION LLC
- Site address
- MIDLAND CROSSING APARTMENTS 165 MIDLAND TRAIL
- City
- HURRICANE
- State
- WV
- ZIP
- 25526
- Mailing
- PO BOX 1081, HURRICANE, WV 25526
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- SIC code (legacy)
- 1522
- Employees
- 12
- Ownership type
- A
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- Aug 7, 2009
- Abate by
- Aug 12, 2009
- Penalty
- Initial $1,500 · Current $1,400 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety & health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were likely to cause death or serious physical harm to employees exposed to crushing injuries in the event of a collapse of the wooden trusses: (a)Structure 1 / 3 Units: The employer had only 1 lateral temporary top chord brace on each side of the 6 in 12 sloped 31 foot wooden trusses and one gable brace in lieu of following the BCSI B1 Summary Sheet which calls for 2 top chord lateral bracing along with diagonal bracing and a gable brace at each location of the lateral braces as observed on 7-16-09. (b)Structure 2 / 3 Units: The employer had only 1 lateral temporary top chord brace on each side of the 6 in 12 sloped 31 foot wooden trusses and one gable brace in lieu of following the BCSI B1 Summary Sheet which calls for 2 top chord lateral bracing along with diagonal bracing and a gable brace at each location of the lateral braces as observed on 7-16-09. (c)Structure 3 / 4 Units: The employer had only 1 lateral temporary top chord brace on each side of the 6 in 12 sloped 31 foot wooden trusses and one gable brace in lieu of following the BCSI B1 Summary Sheet which calls for 2 top chord lateral bracing along with diagonal bracing and a gable brace at each location of the lateral braces as observed on 7-16-09. Abatement Note: Among other methods, one feasible and acceptable abatement to correct this hazard would be to follow the appropriate BCSI guide lines for temporary bracing of wooden trusses.
Recent events (2)
- — I (S) $1400.00
- — Z (S) $1500.00
1910.178 L01
- Issued
- Aug 7, 2009
- Abate by
- Aug 13, 2009
- Penalty
- Initial $1,500 · Current $100 Reduced
Recent events (2)
- — I (S) $100.00
- — Z (S) $1500.00
1926.501 B14
- Issued
- Aug 7, 2009
- Abate by
- Aug 12, 2009
- Penalty
- Initial $1,200 · Current $1,000 Reduced
Recent events (2)
- — I (S) $1000.00
- — Z (S) $1200.00
1926.404 F06
- Issued
- Aug 7, 2009
- Abate by
- Aug 12, 2009
- Penalty
- Initial $120 · Current $100 Reduced
Recent events (2)
- — I (R) $100.00
- — Z (R) $120.00
1926.404 A02
- Issued
- Aug 7, 2009
- Abate by
- Aug 12, 2009
1926.405 G02 IV
- Issued
- Aug 7, 2009
- Abate by
- Aug 12, 2009
More inspections at Dynamic Construction LLC
View Dynamic Construction LLC's full OSHA safety record →
More inspections in this industry (NAICS 236116)
More inspections in WV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 311681183.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.