CLAY, WV —
OSHA Inspection: PIERSON LUMBER CO., INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PIERSON LUMBER CO., INC. in 1500 CLAY HIGHWAY, CLAY, WV 25043 (NAICS 321113). OSHA activity number 311684203.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PIERSON LUMBER CO., INC.
- Site address
- 1500 CLAY HIGHWAY
- City
- CLAY
- State
- WV
- ZIP
- 25043
- Mailing
- P.O. BOX 146, CLAY, WV 25043
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321113
- SIC code (legacy)
- 2421
- Employees
- 25
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 24, 2008
- Abate by
- Dec 12, 2008
- Penalty
- Initial $1,050 · Current $800 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were likely to cause death or serious physical harm to the employees in that employees were exposed to fire hazards: a.Re-saw collecting/blower system - On 08/27/08 and times prior to, employees were exposed to a fire hazard from static charge generation while collecting and blowing a combustible dust through the re-saw dust collection system. Nonmetallic ducts such as PVC pipe and flexible tubing were used to move the saw dust from the re-saw to the saw dust building. NOTE: Among other methods, one feasible and acceptable abatement method to correct this hazard is to follow accepted safe practices such as but not limited to; a) install metallic/conductive duct work to prevent static electric charge generation by the airflow, b) ground and bond metallic duct work, and c) flexible ducting shall be permitted for final machine connection in a length not exceeding the minimum required for machine operation, as addressed in NFPA 664, Standard for the Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities, 2007 Edition, paragraph 7.9.1, 7.9.2, 8.2.2.2.1.1, and 8.2.2.2.1.2.
Recent events (2)
- — I (S) $800.00
- — Z (S) $1050.00
1910.253 B04 III
- Issued
- Oct 24, 2008
- Abate by
- Nov 13, 2008
- Penalty
- Initial $750 · Current $500 Reduced
Recent events (2)
- — I (S) $500.00
- — Z (S) $750.00
1910.265 C20 III
- Issued
- Oct 24, 2008
- Abate by
- Nov 13, 2008
- Penalty
- Initial $1,050 · Current $800 Reduced
Recent events (2)
- — I (S) $800.00
- — Z (S) $1050.00
1910.265 C20 VI
- Issued
- Oct 24, 2008
- Abate by
- Nov 13, 2008
- Penalty
- Initial $1,050 · Current $800 Reduced
Recent events (2)
- — I (S) $800.00
- — Z (S) $1050.00
More inspections at Pierson Lumber CO., INC.
View Pierson Lumber CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321113)
More inspections in WV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 311684203.