MORGANTOWN, WV —
OSHA Inspection: MYLAN PHARMACEUTICALS INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of MYLAN PHARMACEUTICALS INC. in 781 CHESTNUT RIDGE ROAD, MORGANTOWN, WV 26505 (NAICS 325412). OSHA activity number 311685168.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MYLAN PHARMACEUTICALS INC.
- Site address
- 781 CHESTNUT RIDGE ROAD
- City
- MORGANTOWN
- State
- WV
- ZIP
- 26505
- Mailing
- POST OFFICE BOX 4310, MORGANTOWN, WV 26505
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325412
- SIC code (legacy)
- 2834
- Employees
- 1800
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Mar 4, 2009
- Abate by
- Oct 1, 2009
- Penalty
- Initial $2,975 · Current $1,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were likely to cause death or serious physical harm to the employees in that employees were exposed to fire hazards: (a)NEX 512, Production Area: On January 22, 2009 and times prior to, employees were exposed to a fire hazard while charging the fluid bed with powdered ingredients used in the manufacturing of pharmaceuticals. The powdered ingredients were a combustible dust. The drop tube used for charging was not equipped with a device to prevent fire from entering into the work area from the fluid bed. NOTE: Among other methods, one feasible and acceptable abatement method to correct this hazard is to follow accepted safe practices such as but not limited to; (a) installation of an isolation valve between the fluid bed and operator opening of the drop tube, (b) follow the guidelines set forth in NFPA 654, Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible Particulate Solids. ABATEMENT CERTIFICATION REQUIRED FOR THIS ITEM
Recent events (2)
- — I (O) $1000.00
- — Z (S) $2975.00
1910.132 A
- Issued
- Mar 4, 2009
- Abate by
- Mar 30, 2009
Recent events (2)
- — I (S)
- — Z (S)
More inspections at Mylan Pharmaceuticals INC.
View Mylan Pharmaceuticals INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325412)
More inspections in WV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 311685168.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.