Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NEXUS DRILLING CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NEXUS DRILLING CORPORATION in DAISY ROSS #2, RIG 4, ORMA, WV 25268 (NAICS 213111). OSHA activity number 311685903.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nexus Drilling Corporation — free Get an email when a new federal OSHA severe-injury report for Nexus Drilling Corporation is published. One employer, no account, unsubscribe in one click.
Site address
DAISY ROSS #2, RIG 4
City
ORMA
State
WV
ZIP
25268
Mailing
P.O. BOX 903, JANE LEW, WV 26378
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213111
SIC code (legacy)
1381
Employees
13
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 03 1 instance 13 exposed
Issued
May 1, 2009
Abate by
May 20, 2009
Penalty
Initial $1,125 · Current $1,125
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that were likely to cause death or serious physical harm to the employees
in that employees
were exposed to struck by and crushing hazards:
(a)Nexus Drilling, Rig #4, Daisy Ross No. 2 well site - Employees were
performing work on and around the drilling rig.  Employees were exposed to
the hazard of collapse of the derrick/mast in that the employer did not
ensure
that the guy wire anchor spacing/pattern was consistent with the
manufacturer's recommendations or with consensus standards, as determined
on 03/31/09.
NOTE: Among other methods, one feasible and acceptable abatement method to
correct this
hazard is to follow accepted safe practices such as but not limited to; a)
install guy wire
anchors according to the rig manufacturer's recommendations for guying
patterns, or b)
install guy wires according to the Recommended Practice for Use and
Procedures for
Inspection, Maintenance, and Repair of Drilling and Well Servicing
Structures (API
Recommended Practice 4G, 2004), Section 13.1.
ABATEMENT CERTIFICATION REQUIRED FOR THIS ITEM

5(a)(1)

Serious Gravity 03 1 instance 13 exposed
Issued
May 1, 2009
Abate by
Jun 5, 2009
Penalty
Initial $1,125 · Current $1,125
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that were likely to cause death or serious physical harm to the employees
in that employees
were exposed to struck by and crushing hazards:
(a)Nexus Drilling, Rig #4, Daisy Ross No. 2 well site - Employees were
performing work on and around the drilling rig.  Employees were exposed to
the hazard of collapse of the derrick/mast in that the employer did not
ensure
that the anchor capacities were verified prior to attaching guy lines to
the
anchors, as determined on 07/25/08.
NOTE: Among other methods, one feasible and acceptable abatement method to
correct this
hazard is to follow accepted safe practices such as but not limited to ;
a) verify the capacity
of the anchors by pull testing or other method based upon accepted
engineering practices that
yield equivalent results to pull testing, as specified in the Recommended
Practice for Use,
and Procedures for Inspection, Maintenance, and Repair of Drilling and
Well Servicing
Structures (API Recommended Practice 4G, 2004), section 14.5(a), and b)
the employer shall
be responsible for providing anchorage capable of withstanding the maximum
guy line loads,
as specified in the Specification for Drilling and Well Servicing (API
Specification 4E, 1988)
section 3.14.
ABATEMENT CERTIFICATION REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $1125.00
  • — Z (S) $1125.00

1910.23 A08

Serious Gravity 02 1 instance 6 exposed
Issued
May 1, 2009
Abate by
May 20, 2009
Penalty
Initial $900 · Current $900

1910.151 B

Serious Gravity 02 1 instance 13 exposed
Issued
May 1, 2009
Abate by
Jun 4, 2009
Penalty
Initial $900 · Current $400 Reduced
Recent events (2)
  • — I (S) $400.00
  • — Z (S) $900.00

1910.23 C01

Serious Gravity 02 1 instance 6 exposed
Issued
May 1, 2009
Abate by
May 20, 2009
Penalty
Initial $2,400 · Current $2,400
Recent events (2)
  • — I (S) $2400.00
  • — Z (R) $2400.00

View Nexus Drilling Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 311685903.