MARTINSBURG, WV ·
OSHA Inspection: DAVID R. DILL CONCRETE INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DAVID R. DILL CONCRETE INC. in EAST ROAD, MARTINSBURG, WV 26111 (NAICS 236115). OSHA activity number 311686679.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DAVID R. DILL CONCRETE INC.
- Site address
- EAST ROAD
- City
- MARTINSBURG
- State
- WV
- ZIP
- 26111
- Mailing
- 1135 SULFUR SPRING ROAD, MIDDLETOWN, VA 22650
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- SIC code (legacy)
- 1521
- Employees
- 20
- Ownership type
- Private (A)
Citations
9 citations on file for this inspection.
5(a)(1)
- Issued
- Jun 30, 2009
- Abate by
- Jul 8, 2009
- Penalty
- Initial $1,500 · Current $1,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck by/caught between hazards: a.Worksite: Employees were working inside of wooden roof trusses on a residential apartment building. The wooden trusses were not adequately braced in that lateral bracing at the top, middle, and the end of the trusses with diagonal bracing throughout, was missing, as determined on or about 04/28/09. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTANCE METHOD OF ABATEMENT WOULD BE TO FOLLOW THE MANUFACTURER'S RECOMMENDATIONS ON ROOF TRUSS ERECTION OR THE BSCI 1-03 ISSUED BY THE WOOD TRUSS COUNCIL OF AMERICA AND THE TRUSS PLATE INSTITUTE.
1926.25 A
- Issued
- Jun 30, 2009
- Abate by
- Jul 8, 2009
- Penalty
- Initial $600 · Current $600
1926.50 C
- Issued
- Jun 30, 2009
- Abate by
- Jul 8, 2009
- Penalty
- Initial $600 · Current $600
1926.100 A
- Issued
- Jun 30, 2009
- Abate by
- Jul 8, 2009
- Penalty
- Initial $750 · Current $750
1926.20 B02
- Issued
- Jun 30, 2009
- Abate by
- Jul 8, 2009
1926.102 A01
- Issued
- Jun 30, 2009
- Abate by
- Jul 8, 2009
- Penalty
- Initial $750 · Current $750
1926.20 B01
- Issued
- Jun 30, 2009
- Abate by
- Jul 8, 2009
1926.403 B02
- Issued
- Jun 30, 2009
- Abate by
- Jul 8, 2009
- Penalty
- Initial $450 · Current $450
1910.1200 E01
- Issued
- Jun 30, 2009
- Abate by
- Jul 8, 2009
- Penalty
- Initial $450 · Current $450
More inspections in this industry (NAICS 236115)
More inspections in WV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 311686679.