Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ORION ELEVATOR INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of ORION ELEVATOR INC. in 5805 7TH AVE., BROOKLYN, NY 11220 (NAICS 238990). OSHA activity number 311731673.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Orion Elevator INC. — free Get an email when a new federal OSHA severe-injury report for Orion Elevator INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ORION ELEVATOR INC.
Site address
5805 7TH AVE.
City
BROOKLYN
State
NY
ZIP
11220
Mailing
401 BROADWAY, SUITE 603, NEW YORK, NY 10013
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
SIC code (legacy)
1799
Employees
1
Ownership type
A
Industry flags
Construction safety.

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 17, 2008
Abate by
Mar 25, 2008
Penalty
Initial $1,500 · Current $750 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that the
employees were exposed to falling down the elevator shaft or being crushed
by moving elevator.
a)Parking device on the First floor of a passenger elevator.
The elevator shaft door was able to be opened from the outside when the
elevator
was outside of the landing zone floor exposing an employee to a fall of
approximately thirteen feet ten inches to the bottom of the shaft; on or
about
12/12/08.
One feasible and acceptable abatement method, among others, to correct
this hazard is to follow
ASME A 17.3-1996 Safety Code for Existing Elevators. Section 2.7.2
"Elevator Parking
Device" which states that the parking device shall be installed so that
the device will not permit
opening or unlocking a door when the car is outside the landing zone.
NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS
REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE
TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29
CFR 1903.19.0
Recent events (2)
  • — I (S) $750.00
  • — Z (S) $1500.00

View Orion Elevator INC.'s full OSHA safety record →