WHITEFORD, MD ·
OSHA Inspection: PALATIAL DESIGN AND MFG, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of PALATIAL DESIGN AND MFG, INC. in 1632 MAIN STREET, WHITEFORD, MD 21160 (NAICS 321918). OSHA activity number 311852610.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PALATIAL DESIGN AND MFG, INC.
- Site address
- 1632 MAIN STREET
- City
- WHITEFORD
- State
- MD
- ZIP
- 21160
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321918
- SIC code (legacy)
- 2431
- Employees
- 5
- Ownership type
- Private (A)
- Industry flags
- Manufacturing health.
Citations
38 citations on file for this inspection.
1910.110 F02 I
- Issued
- Oct 14, 2008
- Abate by
- Oct 20, 2008
- Penalty
- Initial $500 · Current $100 Reduced
Recent events (2)
- · I (S) $100.00
- · Z (S) $500.00
1910.132 A
- Issued
- Oct 14, 2008
- Abate by
- Nov 17, 2008
- Penalty
- Initial $500 · Current $100 Reduced
Recent events (2)
- · I (S) $100.00
- · Z (S) $500.00
1910.147 C04 I
- Issued
- Oct 14, 2008
- Abate by
- Nov 17, 2008
- Penalty
- Initial $375 · Current $50 Reduced
Recent events (2)
- · I (S) $50.00
- · Z (S) $375.00
1910.147 C05 I
- Issued
- Oct 14, 2008
- Abate by
- Oct 20, 2008
Recent events (2)
- · I (S)
- · Z (S)
1910.147 C06 I
- Issued
- Oct 14, 2008
- Abate by
- Oct 20, 2008
Recent events (2)
- · I (S)
- · Z (S)
1910.147 C07 I
- Issued
- Oct 14, 2008
- Abate by
- Nov 17, 2008
Recent events (2)
- · I (S)
- · Z (S)
1910.157 G01
- Issued
- Oct 14, 2008
- Abate by
- Oct 20, 2008
- Penalty
- Initial $375 · Current $50 Reduced
Recent events (2)
- · I (S) $50.00
- · Z (S) $375.00
1910.178 L01 I
- Issued
- Oct 14, 2008
- Abate by
- Oct 20, 2008
- Penalty
- Initial $375 · Current $50 Reduced
Recent events (2)
- · I (S) $50.00
- · Z (S) $375.00
1910.212 A01
- Issued
- Oct 14, 2008
- Abate by
- Oct 15, 2008
- Penalty
- Initial $625 · Current $100 Reduced
Recent events (2)
- · I (S) $100.00
- · Z (S) $625.00
1910.213 I01
- Issued
- Oct 14, 2008
- Abate by
- Oct 20, 2008
- Penalty
- Initial $625 · Current $100 Reduced
Recent events (2)
- · I (S) $100.00
- · Z (S) $625.00
1910.303 G02 I
- Issued
- Oct 14, 2008
- Abate by
- Oct 20, 2008
- Penalty
- Initial $500 · Current $100 Reduced
Recent events (2)
- · I (S) $100.00
- · Z (S) $500.00
50104 A
- Issued
- Oct 14, 2008
- Abate by
- Nov 17, 2008
- Penalty
- Initial $750 · Current $750
M102
General-duty citation text
Labor and Employment Article, Section 5-104(a): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: (a)Date of Violation:06/23/08 Location:Shop Area Condition:A dust-collection system with a flow rate of 7400 cubic feet per minute, that was used to collect explosive wood dust from a woodworking shop was not designed by and installed under the supervision of qualified engineers knowledgeable of these systems and their associated hazards. Employees were exposed to potential dust explosions, deflagration, and other fire hazards from ungrounded duct work and from the recycling of dust collection system exhaust air back into the building. Among other methods, one feasible and acceptable abatement method to correct this hazard is to have a qualified engineer inspect the dust collector to ensure that it is designed and installed in accordance with National Fire Protection Association (NFPA) 664, Standard for the Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities. Abatement measures may include equipping the exhaust air dust conveying the recycled air back into the building with a high speed abort gate that is activated by a spark detection system and sprinkler system that are in compliance with NFPA 664. Abatement documentation (photographs, receipts, copies of programs, training certification, etc.) is required for this item.
Recent events (2)
- · I (S) $750.00
- · Z (S) $750.00
50104 A
- Issued
- Oct 14, 2008
- Abate by
- Nov 17, 2008
General-duty citation text
Labor and Employment Article, Section 5-104(a): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: (a)Date of Violation:06/23/08 Location:Shop Area Condition:Employees were exposed to fire and deflagration hazards from a 2- horsepower enclosureless duct collector with a flow rate of 1200 cubic feet per minute that was connected to a Bridgewood Sander (BWS 15) having a mechanical material feed and was located less than 20 feet from an area that was routinely occupied by personnel. Among other methods, one feasible and acceptable abatement method to correct this hazard is to have a qualified engineer inspect the dust collector to ensure that it is designed and installed in accordance with National Fire Protection Association (NFPA) 664, Standard for the Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities. Abatement measures may include changing the sander from a mechanically fed sander to a manually fed sander and moving the location of the collector so that it is at least 20 feet from an area routinely occupied by personel or from any means of egress. Abatement documentation (photographs, receipts, copies of programs, training certification, etc.) is required for this item.
Recent events (2)
- · I (S)
- · Z (S)
1910.95 C01
- Issued
- Oct 14, 2008
- Abate by
- Nov 17, 2008
8111
Recent events (2)
- · I (O)
- · Z (O)
1910.132 D02
- Issued
- Oct 14, 2008
- Abate by
- Oct 17, 2008
Recent events (2)
- · I (O)
- · Z (O)
1910.132 F04
- Issued
- Oct 14, 2008
- Abate by
- Oct 15, 2008
Recent events (2)
- · I (O)
- · Z (O)
1910.141 D02 II
- Issued
- Oct 14, 2008
- Abate by
- Oct 15, 2008
Recent events (2)
- · I (O)
- · Z (O)
1910.147 C06 II
- Issued
- Oct 14, 2008
- Abate by
- Oct 20, 2008
Recent events (2)
- · I (O)
- · Z (O)
1910.147 C07 IV
- Issued
- Oct 14, 2008
- Abate by
- Nov 17, 2008
Recent events (2)
- · I (O)
- · Z (O)
1910.157 C01
- Issued
- Oct 14, 2008
- Abate by
- Oct 20, 2008
Recent events (2)
- · I (O)
- · Z (O)
1910.157 E02
- Issued
- Oct 14, 2008
- Abate by
- Oct 20, 2008
Recent events (2)
- · I (O)
- · Z (O)
1910.157 E03
- Issued
- Oct 14, 2008
- Abate by
- Oct 20, 2008
Recent events (2)
- · I (O)
- · Z (O)
1910.178 A06
- Issued
- Oct 14, 2008
- Abate by
- Nov 17, 2008
Recent events (2)
- · I (O)
- · Z (O)
1910.178 L04 III
- Issued
- Oct 14, 2008
- Abate by
- Nov 17, 2008
Recent events (2)
- · I (O)
- · Z (O)
1910.178 L06
- Issued
- Oct 14, 2008
- Abate by
- Nov 17, 2008
Recent events (2)
- · I (O)
- · Z (O)
1910.178 Q06
- Issued
- Oct 14, 2008
- Abate by
- Nov 17, 2008
Recent events (2)
- · I (O)
- · Z (O)
1910.178 Q07
- Issued
- Oct 14, 2008
- Abate by
- Oct 20, 2008
Recent events (2)
- · I (O)
- · Z (O)
1910.242 B
- Issued
- Oct 14, 2008
- Abate by
- Oct 15, 2008
Recent events (2)
- · I (O)
- · Z (O)
1910.303 B02
- Issued
- Oct 14, 2008
- Abate by
- Oct 20, 2008
Recent events (2)
- · I (O)
- · Z (O)
1910.303 F02
- Issued
- Oct 14, 2008
- Abate by
- Oct 20, 2008
Recent events (2)
- · I (O)
- · Z (O)
1910.303 G01 II
- Issued
- Oct 14, 2008
- Abate by
- Oct 20, 2008
Recent events (2)
- · I (O)
- · Z (O)
1910.305 B01 II
- Issued
- Oct 14, 2008
- Abate by
- Oct 15, 2008
Recent events (2)
- · I (O)
- · Z (O)
1910.305 B02
- Issued
- Oct 14, 2008
- Abate by
- Oct 20, 2008
Recent events (2)
- · I (O)
- · Z (O)
1910.305 G01 III
- Issued
- Oct 14, 2008
- Abate by
- Oct 20, 2008
Recent events (2)
- · I (O)
- · Z (O)
1910.1200 E01
- Issued
- Oct 14, 2008
- Abate by
- Nov 17, 2008
Recent events (2)
- · I (O)
- · Z (O)
1910.1200 H01
- Issued
- Oct 14, 2008
- Abate by
- Oct 15, 2008
Recent events (2)
- · I (O)
- · Z (O)
50405 B01
- Issued
- Oct 14, 2008
- Abate by
- Oct 20, 2008
Recent events (2)
- · I (O)
- · Z (O)
50406 A01
- Issued
- Oct 14, 2008
- Abate by
- Nov 3, 2008
Recent events (2)
- · I (O)
- · Z (O)
More inspections in this industry (NAICS 321918)
More inspections in MD
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 311852610.