CONNEAUTVILLE, PA ·
OSHA Inspection: P S FURNITURE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of P S FURNITURE in 801 HIGH STREET, CONNEAUTVILLE, PA 16406 (NAICS 337127). OSHA activity number 311875884.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- P S FURNITURE
- Site address
- 801 HIGH STREET
- City
- CONNEAUTVILLE
- State
- PA
- ZIP
- 16406
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337127
- SIC code (legacy)
- 2531
- Employees
- 34
- Ownership type
- Private (A)
Citations
8 citations on file for this inspection.
5(a)(1)
- Issued
- Jun 10, 2010
- Abate by
- Oct 29, 2010
- Penalty
- Initial $1,250 · Current $1,250
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to dust collectors located inside buildings: a) P S Furniture, plywood building, near CNC router and saws - On or about 1/20/10, the wood dust collectors located inside the building contained explosive dust. The building and the employees were exposed to a potential explosion hazard from wood dust in the dust collector. 1.) One - 4 bag enclosureless dust collector (Dustek 15 horse motor unit) servicing the CNC router. 2.) Two - 2 bag enclosureless dust collectors (1-2 bag Dustek 10 horse motor unit; and 1-2 bag Grizzly 10 horse power unit) servicing the powermatic saws. Abatement Note: Among other methods, one feasible and acceptable abatement method to correct the hazard is to: (1) Relocate the dust collection system to the exterior of the building. OR (2) Another feasible and acceptable abatement method to correct this hazard would be to ensure that enclosureless dust collectors which are used indoors are installed in a manner that minimizes fire and explosion hazards to employees at nearby work stations and other nearby enclosureless dust collectors. In Accordance with the National Fire Prevention Association (NFPA) 664-2007 Standard for the Prevention of Fires and Explosions in Wood Processing and Woodworking facilities. The criteria that need to be met in order to allow a dust collector indoors are (**NOTE** all the criteria must be met): 1) The collector is used only for dust pickup from wood processing machinery; 2) The collector is not used on sanders or abrasive planners having mechanical material feeds; 3) The fan motor is totally enclosed, fan-cooled design; 4) The collected dust is removed daily or more frequently if necessary to ensure efficient operation; 5) The collector is located at least 20 ft. from any means of egress or area routinely occupied by personnel {Note Per NFPA 101 Life Safety Code -- The means of egress consists of exit routes, the exit door, and the public way (i.e. safe zone outside the building} 6) Multiple collectors in the same room are separated from each other by at least 20 ft. 7) Collector can not exceed a maximum air handling capacity of 5,000 CFM. (Note: Manufactures literature indicates that the 4-bag unit can exceed 5,000 CFM).
Recent events (3)
- · P (S) $1250.00
- · I (S) $1250.00
- · Z (S) $1250.00
1910.132 D02
- Issued
- Jun 10, 2010
- Abate by
- Sep 15, 2010
- Penalty
- Initial $750 · Current $100 Reduced
Recent events (2)
- · I (S) $100.00
- · Z (S) $750.00
1910.147 C04 II
- Issued
- Jun 10, 2010
- Abate by
- Sep 15, 2010
- Penalty
- Initial $1,750 · Current $1,750
Recent events (2)
- · I (S) $1750.00
- · Z (S) $1750.00
1910.147 C06 I
- Issued
- Jun 10, 2010
- Abate by
- Sep 15, 2010
Recent events (2)
- · I (S)
- · Z (S)
1910.147 C07 I
- Issued
- Jun 10, 2010
- Abate by
- Sep 15, 2010
Recent events (2)
- · I (S)
- · Z (S)
1910.178 L04 III
- Issued
- Jun 10, 2010
- Abate by
- Jul 6, 2010
- Penalty
- Initial $1,000 · Current $500 Reduced
Recent events (2)
- · I (S) $500.00
- · Z (S) $1000.00
1910.303 B01 I
- Issued
- Jun 10, 2010
- Abate by
- Jul 6, 2010
- Penalty
- Initial $750
Recent events (2)
- · I (O)
- · Z (S) $750.00
1910.305 G01 IV
- Issued
- Jun 10, 2010
- Abate by
- Sep 15, 2010
- Penalty
- Initial $750
Recent events (2)
- · I (O)
- · Z (S) $750.00
More inspections at P S Furniture
View P S Furniture's full OSHA safety record →
More inspections in this industry (NAICS 337127)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 311875884.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.