Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CLARION BATHWARE, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CLARION BATHWARE, INC. in 16273 RT. 208, MARBLE, PA 16334 (NAICS 326199). OSHA activity number 311881429.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Clarion Bathware, INC. — free Get an email when a new federal OSHA severe-injury report for Clarion Bathware, INC. is published. One employer, no account, unsubscribe in one click.
Site address
16273 RT. 208
City
MARBLE
State
PA
ZIP
16334
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
SIC code (legacy)
3089
Employees
100
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 05 1 instance 10 exposed
Issued
Sep 8, 2011
Abate by
Jan 1, 2012
Penalty
Initial $3,500 · Current $2,625 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that were causing or likely to cause death or serious physical harm to
employees in that
employees were exposed to potential explosion, deflagrations, and flame
fronts entering back
into the building due to a lack of isolation devices on the dust
collection equipment and
associated duct work:
A)  Clarion Bathware Inc.; baghouse outside of Grinding Room (Eurovac
Model #RLO-40-
0550-2030) - On or about 7/1/11, the dust collector/bag house and its
associated duct work
did not have any isolation devices.  The lack of isolation devices could
allow an explosion
originating in the dust collector/bag house to propagate back into the
building.  Condition
potentially exposed personnel to the hazards associated with dust
explosions/deflagrations.
The bag house services operations for the grinding room.
ABATEMENT NOTE:
Among other methods, feasible and acceptable means to correct the
conditions  are to comply
with applicable requirements noted in NFPA 654 and the installation of
approved isolation
devices.
Recent events (3)
  • — P (S) $2625.00
  • — I (S) $2625.00
  • — Z (S) $3500.00

View Clarion Bathware, INC.'s full OSHA safety record →