Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BALLAST BOB'S LIGHTING SERVICE, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BALLAST BOB'S LIGHTING SERVICE, INC. in 1410 GRAND AVE., GLENWOOD SPRINGS, CO 81601 (NAICS 561790). OSHA activity number 311903132.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ballast Bob'S Lighting Service, INC. — free Get an email when a new federal OSHA severe-injury report for Ballast Bob'S Lighting Service, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1410 GRAND AVE.
City
GLENWOOD SPRINGS
State
CO
ZIP
81601
Mailing
1877 BROADWAY, GRAND JUNCTION, CO 81503
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561790
SIC code (legacy)
7349
Employees
2
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 01 1 instance 1 exposed
Issued
May 23, 2008
Abate by
Jun 19, 2008
Penalty
Initial $225 · Current $100 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that were causing or likely to cause death or serious physical harm to
employees in that
employees were exposed to a potential fall hazard associated with lifting
personnel in an
unstable aerial lift:
(a)Ballast Bob's Lighting Service, Inc. & 1410 Grand Ave, Glenwood
Springs, CO 81601: The Bil-Jax model # XLB-4232, hydraulic boom lift,
missing outrigger pads, was used to lift employees approximately 15 feet to
perform maintenance on a sign outside the City Market supermarket. This
condition exposed the employee to a fall hazard of approximately 10 feet
due
to the instability of the lift..
Among other methods, one feasible and acceptable abatement method to
correct this hazard
is to follow manufacturer's requirements associated with general safety
precautions before
operating the XLB-4232:
1-2 Before Operation
Always inspect the equipment for damaged or worn parts. Check for cracked
welds,
hydraulic leaks, damaged wiring, loose wire connectors, damaged
outriggers, low
tire pressure, uneven tire wear, or tire damage. Also check for any
improper
operation. NEVER operate equipment if damaged in any way. Improperly
operating
equipment must be repaired before using.
Abatement Note:  Abatement certification is required for this item (see
enclosed "Sample
Abatement-Certification Letter").
Recent events (2)
  • — I (S) $100.00
  • — Z (S) $225.00

1910.67 C02 II

Serious Gravity 01 1 instance 1 exposed
Issued
May 23, 2008
Abate by
Jun 19, 2008
Penalty
Initial $225 · Current $100 Reduced
Recent events (2)
  • — I (S) $100.00
  • — Z (S) $225.00

1910.67 C02 V

Serious Gravity 01 1 instance 1 exposed
Issued
May 23, 2008
Abate by
Jun 19, 2008
Penalty
Initial $225 · Current $100 Reduced
Recent events (2)
  • — I (S) $100.00
  • — Z (S) $225.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 311903132.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.