GILL, CO —
OSHA Inspection: HETTINGER MAYO LLC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of HETTINGER MAYO LLC. in LARSON COMPRESSOR GATHERING STATION, GILL, CO 80624 (NAICS 213112). OSHA activity number 311905624.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HETTINGER MAYO LLC.
- Site address
- LARSON COMPRESSOR GATHERING STATION
- City
- GILL
- State
- CO
- ZIP
- 80624
- Mailing
- 230 COMMERCE DRIVE, BERTHOUD, CO 80634
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- SIC code (legacy)
- 1389
- Employees
- 8
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 22, 2008
- Abate by
- Oct 7, 2008
- Penalty
- Initial $4,000 · Current $5,000
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of burns and/or asphyxiation: a) Hettinger Mayo LLC., Larson Compressor Gathering Station, Gill, Colorado: The employer had not ensured that on and prior to July 18, 2008, lockout procedures were implemented to ensure that the two new ANSI 600 valves between the pressurized 4" production gas line and new compressor and scrubber unit were locked out to prevent the release of pressurized flammable gas. Among other methods, one feasible and acceptable abatement method to correct this hazard is to develop and implement a Hazardous Energy Control Program in accordance with the American National Standard Institute (ANSI) Z.244.5-2003 thus ensuring that all energy isolating devices (valves) are identified and equipped with locks and tags. b) The employer had not ensured that on and prior to July 17, 2008, lockout procedures were implemented to ensure that the new valve installed between an existing 300 barrel storage tank and existing 3" drip line was locked and tagged to prevent the release of flammable gas. On July 17th, 2008, while employees were cutting the 3" drip line with an oxygen/acetylene torch, the 300 barrel storage tank containing flammable vapor exploded. Among other methods, one feasible and acceptable abatement method to correct this hazard is to develop and implement a Hazardous Energy Control Program in accordance with the American National Standard Institute (ANSI) Z.244.5-2003 thus ensuring that all energy isolating devices (valves) are identified and equipped with locks and tags to prevent the unexpected release of flammable gas. c) The employer had not ensured that prior to cutting an existing 3" steel drip line attached to a 300 barrel tank containing flammable gas, the line was ventilated and tested to ensure the absence of flammable substances. On and prior to July 17th, 2008, while employees of the company were cutting various sections of the pipe using an oxygen/acetylene torch, the 300 barrel tank exploded. Condition exposed employees to "struck by" and/or "burn" hazards. Abatement Note: Abatement certification and documentation are required for this item (See enclosed "Sample Abatement-Certification Letter").-Certification
Recent events (2)
- — I (S) $5000.00
- — Z (S) $4000.00
1926.352 I
- Issued
- Sep 22, 2008
- Abate by
- Oct 7, 2008
- Penalty
- Initial $4,000 · Current $4,000
Recent events (2)
- — I (S) $4000.00
- — Z (S) $4000.00
More inspections at Hettinger Mayo LLC.
View Hettinger Mayo LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 213112)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 311905624.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.