RIFLE, CO —
OSHA Inspection: HALLIBURTON ENERGY SERVICES INC.
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of HALLIBURTON ENERGY SERVICES INC. in LEVERICH 31-13B, RIFLE, CO 80202 (NAICS 213112). OSHA activity number 311907836.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HALLIBURTON ENERGY SERVICES INC.
- Site address
- LEVERICH 31-13B
- City
- RIFLE
- State
- CO
- ZIP
- 80202
- Mailing
- 3199 D ROAD, GRAND JUNCTION, CO 81504
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- SIC code (legacy)
- 1389
- Employees
- 10000
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Feb 11, 2009
- Abate by
- Jun 1, 2009
- Penalty
- Initial $5,000 · Current $3,500 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were likely to cause death or serious physical harm to employees in that employees were exposed to struck by hazards: (a)Halliburton at Leverich 31-13B, near Rifle, CO 80202: On September 8, 2008 the employer did not ensure the safety of employees on site in that the controls of the AMS4A046 winch operators panel were not adequately monitored by the operator of the winch. The depth alarm was set for 500 feet, however steps were not taken to activate the line tension adjustment valve or other measures to control the speed of the wireline. This condition exposed two operators to a struck by hazard as the tools came up out of the well head, hit the sheave, and consequently fell. Abatement Note: Among other methods, one feasible and acceptable abatement method to correct this hazard is to perform the following: Revise and clarify the current Risk Analysis Chart for Winch Operations to, among other things, require the use of the Company's Depth and Tension Record ("Z-chart") and to add more detail on the safe use of the line tension adjustment valve. All winch operators in the State of Colorado shall be trained on the revised Risk Analysis Chart. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Sample Abatement-Certification Letter").-Certification
Recent events (2)
- — I (S) $3500.00
- — Z (S) $5000.00
More inspections at Halliburton Energy Services INC.
View Halliburton Energy Services INC.'s full OSHA safety record →
More inspections in this industry (NAICS 213112)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 311907836.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.