CRAIG, CO —
OSHA Inspection: KK MECHANICAL
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of KK MECHANICAL in 750 HOSPITAL LOOP, CRAIG, CO 81625 (NAICS 238220). OSHA activity number 311911655.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KK MECHANICAL
- Site address
- 750 HOSPITAL LOOP
- City
- CRAIG
- State
- CO
- ZIP
- 81625
- Mailing
- 1858 WEST 5150 SOUTH, ROY, UT 84067
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- Yes
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- SIC code (legacy)
- 1711
- Employees
- 18
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Aug 25, 2009
- Abate by
- Sep 10, 2009
- Penalty
- Initial $3,500 · Current $3,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of "struck by" a steel end cap and coupler assembly from a pipe undergoing pressure testing. a) KK Mechanical, 750 Hospital Loop, Craig, CO: On or about April 21, 2009, an employee was seriously injured after being struck by a metal end cap and coupler assembly that separated from a six (6) inch pipe undergoing a pressure test. The new pipe installation was located in area 3 on the first floor of the new hospital, and undergoing a pressure test with approximately 80 psi of compressed air when it failed. The injured employee was performing a job task unrelated to the pressure test. b) KK Mechanical, 750 Hospital Loop, Craig, CO: On or about April 21, 2009, an employee was seriously injured after being struck by a metal end cap and coupler assembly that separated from a six (6) inch pipe undergoing a pressure test. The Grinnell brand (figure 772) coupler had not been secured according ot the manufacturer's specification to provide 100-130 lbs/ft. of torque for adequate attachment. Among other methods, one feasible and acceptable abatement method to correct this hazard is to adopt the American Society of Mechanical Engineers (ASME) B31.1-2007 code for pressure piping. Section 137 titled Pressure Tests states in paragraph 137.1.3 that suitable precautions in the event of piping system rupture shall be taken to eliminate hazards to personnel in the proximity of lines being tested. Abatement Note: Abatement certification is required for this item (See enclosed "Sample Abatement-Certification Letter").
More inspections at KK Mechanical
View KK Mechanical's full OSHA safety record →
More inspections in this industry (NAICS 238220)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 311911655.