On , OSHA opened a referral safety inspection of ACME ALLIANCE, LLC in 3610 COMMERCIAL AVENUE, NORTHBROOK, IL 60062 (NAICS 331521). OSHA activity number 311942718.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Acme Alliance, LLC — free Get an email when a new federal OSHA severe-injury report for Acme Alliance, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
ACME ALLIANCE, LLC
Site address
3610 COMMERCIAL AVENUE
City
NORTHBROOK
State
IL
ZIP
60062
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331521
SIC code (legacy)
3363
Employees
120
Ownership type
A

11 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 12, 2008
Abate by
Sep 17, 2008
Penalty
Initial $4,000 · Current $3,000 Reduced

Hazardous substances E101

Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the hazards of fire and or explosion due to the unsafe
methods of  collecting
aluminum dust.
a) Acme Alliance, LLC, Blue Value Stream - CarboTech Wet-Type Dust
Collector, Model
6MV4, Serial Number CV306, manufactured in September, 2001 and installed
in November,
2006. Metal dust containing aluminum collected in the duct on April 3,
2008 is a class ST1
explosive material. An explosion at this dust collector occurred on April
2, 2008 during
maintenance operations. The following conditions found at the facility
increase
the potential for
an explosion and/or severity of an explosion: Where aluminum or aluminum
alloys are subjected
to processing or finishing operations, machines connected to a dust
collection system did not
have suction and capture velocity to collect and transport all the dust
produced; the exhaust vent
was not inspected and cleaned frequently to prevent buildup of highly
combustible deposits of
metal dusts on the interior surfaces of the duct; a thorough inspection of
the dust collector
operating area did not take place to help ensure that the equipment is in
good condition and that
proper work practices are being followed.
General methods of abatement, among others is to adhere to the
requirements in the National
Fire Protection Association (NFPA) 484, Standard for Combustible Metals,
2006, relating to
minimization of the occurrence of and resulting damage from fire and
explosion in areas where
combustible metal dusts are produced.
No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $3000.00
  • — Z (S) $4000.00

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 12, 2008
Abate by
Sep 17, 2008
Penalty
Initial $4,000 · Current $3,000 Reduced

Hazardous substances E101

Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the hazard of fire and or explosion due to the
accumulation of hydrogen gas in
a wet-type dust collector when collecting aluminum dust.
a) Acme Alliance, LLC, Blue Value Stream - CarboTech Wet-Type Dust
Collector, Model
6MV4, Serial Number CV306, manufactured in September, 2001 and installed
in November,
2006. Metal dust containing aluminum collected in the duct on April 3,
2008 is a class ST1
explosive material. An explosion at this dust collector occurred on April
2, 2008 during
maintenance operations. The following conditions found at the facility
increase the potential for
an explosion and/or severity of an explosion:  Where aluminum or aluminum
alloys are
subjected to processing or finishing operations, ventilation of the
collector
sump was not
provided by an independent blower or by an unimpeded vent when the dust
collector was not
in operation, thereby allowing the accumulation of hydrogen gas.
General methods of abatement, among others is to adhere to the
requirements in the National
Fire Protection Association (NFPA) 484, Standard for Combustible Metals,
2006, relating to
minimization of the occurrence of and resulting damage from fire and
explosion in areas where
combustible metal dusts are produced.
No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $3000.00
  • — Z (S) $4000.00

1910.94 A04 IB

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 12, 2008
Abate by
Sep 17, 2008
Penalty
Initial $4,000 · Current $2,800 Reduced
Recent events (2)
  • — I (S) $2800.00
  • — Z (S) $4000.00

1910.94 A07

Serious Gravity 03 1 instance 3 exposed
Issued
Sep 12, 2008
Abate by
Sep 17, 2008
Penalty
Initial $2,000 · Current $1,400 Reduced

Hazardous substances E101

Recent events (2)
  • — I (S) $1400.00
  • — Z (S) $2000.00

1910.145 C03

Serious Gravity 03 1 instance 2 exposed
Issued
Sep 12, 2008
Abate by
Sep 17, 2008
Penalty
Initial $2,000 · Current $1,400 Reduced

Hazardous substances E101

Recent events (2)
  • — I (S) $1400.00
  • — Z (S) $2000.00

1910.1200 H03 II

Serious Gravity 03 1 instance 3 exposed
Issued
Sep 12, 2008
Abate by
Oct 30, 2008

Hazardous substances E101

Recent events (2)
  • — I (S)
  • — Z (S)

1910.157 D01

Serious Gravity 03 1 instance 92 exposed
Issued
Sep 12, 2008
Abate by
Oct 24, 2008
Penalty
Initial $2,000 · Current $1,400 Reduced
Recent events (2)
  • — I (S) $1400.00
  • — Z (S) $2000.00

1910.157 G01

Serious Gravity 03 1 instance 46 exposed
Issued
Sep 12, 2008
Abate by
Sep 17, 2008
Penalty
Initial $2,000 · Current $1,400 Reduced
Recent events (2)
  • — I (S) $1400.00
  • — Z (S) $2000.00

1910.157 G02

Serious Gravity 03 1 instance 92 exposed
Issued
Sep 12, 2008
Abate by
Sep 17, 2008
Recent events (2)
  • — I (S)
  • — Z (S)

1910.335 A01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 12, 2008
Abate by
Oct 24, 2008
Penalty
Initial $4,000 · Current $2,800 Reduced
Recent events (2)
  • — I (S) $2800.00
  • — Z (S) $4000.00

1910.335 A02 I

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 12, 2008
Abate by
Oct 24, 2008
Penalty
Initial $4,000 · Current $2,800 Reduced
Recent events (2)
  • — I (S) $2800.00
  • — Z (S) $4000.00

View Acme Alliance, LLC's full OSHA safety record →