Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TEXAS CES, INC. DBA WESTERN BENTONITE

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of TEXAS CES, INC. DBA WESTERN BENTONITE in HUNTER RANCH J 1-H, DENTON, TX 76207 (NAICS 213111). OSHA activity number 311950240.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Texas CES, INC. DBA Western Bentonite — free Get an email when a new federal OSHA severe-injury report for Texas CES, INC. DBA Western Bentonite is published. One employer, no account, unsubscribe in one click.
Site address
HUNTER RANCH J 1-H
City
DENTON
State
TX
ZIP
76207
Mailing
119 JOHN STREET, ALEDO, TX 76008
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213111
SIC code (legacy)
1381
Employees
13
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Aug 20, 2009
Abate by
Aug 26, 2009
Penalty
Initial $4,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to electrical hazards:
On or about May 28, 2009 and times prior thereto, the employer did not
ensure that the
mud/gray water tank was grounded exposing the employees to electrical
hazards such as, but not
limited to electrical shock and electrocution.
Among other methods, one feasible and acceptable means to abate this
hazard is to ensure all
equipment is properly grounded in accordance with RP 54, Section 6.1.16.