CARLISLE, NY —
OSHA Inspection: INTERSTATE HOME IMPROVEMENTS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of INTERSTATE HOME IMPROVEMENTS, INC. in 299 LAWTON RD., CARLISLE, NY 12092 (NAICS 238130). OSHA activity number 311974315.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INTERSTATE HOME IMPROVEMENTS, INC.
- Site address
- 299 LAWTON RD.
- City
- CARLISLE
- State
- NY
- ZIP
- 12092
- Mailing
- P.O. BOX 243/2858 MAIN ST., SUMMIT, NY 12175
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- SIC code (legacy)
- 1751
- Employees
- 4
- Ownership type
- A
Citations
9 citations on file for this inspection.
5(a)(1)
- Issued
- Nov 25, 2008
- Abate by
- Dec 15, 2008
- Penalty
- Initial $1,500 · Current $1,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that: a)Jobsite - on or about September 16, 2008 - employees were exposed to a struck by hazard while installing wood trusses. The temporary diagonal bracing did not have the requisite fasteners installed to properly hold the trusses in place prior to permanent roof sheeting installations. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE MEANS OF ABATEMENT INCLUDE FOLLOWING THE GUIDELINES SET FORTH IN THE BUILDING COMPONENT SAFETY INFORMATION (BCSI) GUIDE, TRUSS INSTALLATION & TEMPORARY RESTRAINT/BRACING; SECTION B2, WHICH STATES: "FOR ALL BRACING AND LATERAL RESTRAINT MEMBERS, NAIL AS FOLLOWS - USE AT LEAST 2-10d (0.128 x 3"), 2-12d (0.128 x 3.5") OR 2-16d (0.131 x 3.5") NAILS INTO EACH TRUSS FOR BOTH LATERAL RESTRAINT AND DIAGONAL BRACING MEMBERS." ABATEMENT DOCUMENTATION REQUIRED FOR THIS ITEM.
1926.451 B01 I
- Issued
- Nov 25, 2008
- Abate by
- Dec 15, 2008
- Penalty
- Initial $1,500 · Current $1,500
1926.451 B04
- Issued
- Nov 25, 2008
- Abate by
- Dec 15, 2008
- Penalty
- Initial $1,500 · Current $1,500
1926.451 B05 II
- Issued
- Nov 25, 2008
- Abate by
- Dec 15, 2008
- Penalty
- Initial $1,500 · Current $1,500
1926.451 B06
- Issued
- Nov 25, 2008
- Abate by
- Dec 15, 2008
- Penalty
- Initial $1,500 · Current $1,500
1926.451 F07
- Issued
- Nov 25, 2008
- Abate by
- Dec 15, 2008
- Penalty
- Initial $1,500 · Current $1,500
1926.454 A
- Issued
- Nov 25, 2008
- Abate by
- Dec 15, 2008
- Penalty
- Initial $1,500 · Current $1,500
1926.1053 B04
- Issued
- Nov 25, 2008
- Abate by
- Dec 15, 2008
- Penalty
- Initial $1,500 · Current $1,500
1926.1060 A01 III
- Issued
- Nov 25, 2008
- Abate by
- Dec 15, 2008
- Penalty
- Initial $1,500 · Current $1,500
More inspections at Interstate Home Improvements, INC.
View Interstate Home Improvements, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 311974315.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.