RAYNHAM, MA —
OSHA Inspection: ELECTROCHEM SOLUTIONS INCORPORATED
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ELECTROCHEM SOLUTIONS INCORPORATED in 670 PARAMOUNT DRIVE, RAYNHAM, MA 02767 (NAICS 335912). OSHA activity number 312107055.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ELECTROCHEM SOLUTIONS INCORPORATED
- Site address
- 670 PARAMOUNT DRIVE
- City
- RAYNHAM
- State
- MA
- ZIP
- 02767
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335912
- SIC code (legacy)
- 3692
- Employees
- 243
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Jan 7, 2010
- Abate by
- Feb 25, 2010
- Penalty
- Initial $7,000 · Current $6,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to explosion hazards and impact from materials: Dry Room: Employees working at the manual filling station were exposed to explosion hazards from batteries venting inside the filling station. On August 13, 2009, an explosion occurred inside manual filling station injuring two employees. Among other methods, feasible and acceptable abatement methods to correct the hazard are 1) install explosion venting so that overpressure is vented to a safe location away from employees or 2) design the manual filling station enclosure to withstand the maximum amount of overpressure inside the station.sure
Recent events (2)
- — I (S) $6000.00
- — Z (S) $7000.00
More inspections at Electrochem Solutions Incorporated
View Electrochem Solutions Incorporated's full OSHA safety record →
More inspections in this industry (NAICS 335912)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 312107055.