LENOIR, NC —
OSHA Inspection: CALDWELL COUNTY SCHOOLS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CALDWELL COUNTY SCHOOLS in BUS GARAGE, LENOIR, NC 28645 (NAICS 485410). OSHA activity number 312107766.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CALDWELL COUNTY SCHOOLS
- Site address
- BUS GARAGE
- City
- LENOIR
- State
- NC
- ZIP
- 28645
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 485410
- SIC code (legacy)
- 4151
- Employees
- 13
- Ownership type
- B
- Industry flags
- Manufacturing safety.
Citations
8 citations on file for this inspection.
95012901
- Issued
- Aug 8, 2008
- Abate by
- Sep 25, 2008
- Penalty
- Initial $875 · Current $350 Reduced
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish to each of his employees conditions of employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: a)Site: Employer did not develop, implement, and maintain a process of frequent and periodic inspections of the three hoist systems operated in the facility. REFERENCE:ANSI/ASME B30.11 - Monorails and Underhung Cranes Chapter 11-2 - Inspection, Testing, and Maintenance Section 11-2.1.2 - Frequent Inspections: a)Frequent inspections shall be performed at intervals defined in paragraph 11-2.1.1(b)(1) [normal service - monthly] and shall include observations during operation. Section 11-2.1.3 - Periodic Inspections: a)Periodic inspections shall be performed at intervals defined in paragraph 11-2.1.1(b)(2) [normal service, equipment in place, annually. NOTE:Among other methods, one feasible and acceptable method to correct this hazard is to implement a process of inspections by competent individuals of the three hoist systems following the schedule and inspection criteria outlined in ANSI/ASME B30-11, Chapter 11-2.er
Recent events (2)
- — I (S) $350.00
- — Z (S) $875.00
1910.178 L01 I
- Issued
- Aug 8, 2008
- Abate by
- Sep 25, 2008
1910.179 H04
- Issued
- Aug 8, 2008
- Abate by
- Sep 4, 2008
1910.184 E01
- Issued
- Aug 8, 2008
- Abate by
- Sep 4, 2008
1910.184 E03 I
- Issued
- Aug 8, 2008
- Abate by
- Sep 4, 2008
1910.215 A04
- Issued
- Aug 8, 2008
- Abate by
- Aug 20, 2008
1910.242 B
- Issued
- Aug 8, 2008
- Abate by
- Sep 4, 2008
1910.303 B01 I
- Issued
- Aug 8, 2008
- Abate by
- Aug 20, 2008