Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NORTH TEXAS BRIDGE CO., INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NORTH TEXAS BRIDGE CO., INC. in S. CENTRAL EXPY & US HWY 175, DALLAS, TX 75201 (NAICS 237310). OSHA activity number 312119076.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch North Texas Bridge CO., INC. — free Get an email when a new federal OSHA severe-injury report for North Texas Bridge CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
S. CENTRAL EXPY & US HWY 175
City
DALLAS
State
TX
ZIP
75201
Mailing
9425 CR 423, ANNA, TX 75409
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237310
SIC code (legacy)
1611
Employees
25
Ownership type
A
Industry flags
Construction safety.

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 4 exposed
Issued
Dec 11, 2008
Abate by
Dec 16, 2008
Penalty
Initial $1,500 · Current $1,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that were causing or likely to cause death or serious physical harm to
employees in that on or
about November 04, 2008, and at times prior thereto at a workplace located
at South Central
Expressway & US Highway 175, Dallas, Texas: at least four employees were
exposed to a
tip over and struck-by hazard by exceeding the maximum platform capacity
of a Genie S-40
Stick Boom Personnel lift.
Among other feasible methods, one feasible and acceptable means of
abatement includes but
is not limited to following the manufacturers requirement that occupants,
equipment and
materials do not exceed the maximum capacity of the platform of not more
than 2 occupants
and a maximum capacity of 500 pounds.y

1926.100 A

Serious Gravity 02 1 instance 1 exposed
Issued
Dec 11, 2008
Abate by
Dec 16, 2008
Penalty
Initial $600 · Current $600

1926.102 A01

Serious Gravity 02 1 instance 1 exposed
Issued
Dec 11, 2008
Abate by
Dec 16, 2008

1926.453 B02 V

Serious Gravity 10 1 instance 5 exposed
Issued
Dec 11, 2008
Abate by
Dec 19, 2008
Penalty
Initial $1,500 · Current $1,500

1926.501 B01

Serious Gravity 10 1 instance 5 exposed
Issued
Dec 11, 2008
Abate by
Dec 19, 2008
Penalty
Initial $1,500 · Current $1,500

1926.1051 A

Serious Gravity 02 1 instance 7 exposed
Issued
Dec 11, 2008
Abate by
Dec 19, 2008
Penalty
Initial $600 · Current $600

View North Texas Bridge CO., INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 312119076.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.