Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THEDFORD CONSTRUCTION COMPANY, INC.

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of THEDFORD CONSTRUCTION COMPANY, INC. in 19364 HIDDEN LAKE DR., TYLER, TX 75703 (NAICS 237130). OSHA activity number 312120215.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Thedford Construction Company, INC. — free Get an email when a new federal OSHA severe-injury report for Thedford Construction Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
19364 HIDDEN LAKE DR.
City
TYLER
State
TX
ZIP
75703
Mailing
5117 STEEL RD., TYLER, TX 75703
Inspection type
Accident-driven (A)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237130
SIC code (legacy)
1623
Employees
12
Ownership type
A
Industry flags
Construction safety.

12 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 14, 2009
Abate by
Aug 27, 2009
Penalty
Initial $3,500 · Current $1,750 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish
employment and a place of employment free from recognized hazards that
were causing or likely
to cause death or serious physical harm to employees in that employees are
expose to death or
serious injury from an arc flashing. This violation was discovered on or
about February 18,
2009, at a workplace located at 19364 Hidden Lake Dr., Tyler, TX 75703
where at least one
(1) employee, who opened an energized pad-mounted transformer and was
exposed to the
hazards of arc flash, did not wear personal protective equipment.
AMONG OTHER METHODS, AT LEAST ONE FEASIBLE AND ACCEPTABLE MEANS
TO ABATE THIS HAZARD INCLUDES, BUT IS NOT LIMITED TO:
Implement the elements required by the National Electric Safety Code for
the selection and use
of personal protective equipment including but not limited to: face
shield, flame-resistant neck
protection and clothing of the appropriate arc thermal performance value
(ATPV), and rubber
insulating gloves.
Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date
of this citation, the
employer must submit documentation showing that it is in compliance with
the requirement,
including describing the steps that it is taking to ensure that the
appropriate personal protective
equipment (i.e. face shield, flame-resistant neck protection and clothing
of the appropriate
ATPV, and rubber insulating gloves, etc.) is being selected and used.
Or in the Alternative:
29 CFR 1926.95(a): Protective equipment, including personal protective
equipment for eyes,
face, head, and extremities, protective clothing, respiratory devices, and
protective shields and
barriers, were not provided:
This violation was discovered on or about February 18, 2009, at a
workplace
located at 19364
Hidden Lake Dr., Tyler, TX 75703 where at least one (1) employee, who
opened an energized
pad-mounted transformer and was exposed to the hazards of arc flash, did
not wear personal
protective equipment including but not limited to: face shield,
flame-resistant neck protection and
clothing of the appropriate arc thermal performance value (ATPV), and
rubber insulating gloves.
Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date
of this citation, the
employer must submit documentation showing that it is in compliance with
the requirement,
including describing the steps that it is taking to ensure that the
appropriate personal protective
equipment (i.e. face shield, flame-resistant neck protection and clothing
of the appropriate
ATPV, and rubber insulating gloves, etc.) is being selected and used.
Recent events (2)
  • — F (S) $1750.00
  • — Z (S) $3500.00

1926.20 B01

Serious Gravity 10 1 instance 4 exposed
Issued
Aug 14, 2009
Abate by
Aug 27, 2009
Penalty
Initial $1,750 · Current $1,750
Recent events (2)
  • — F (S) $1750.00
  • — Z (S) $1750.00

1926.21 B02

Serious Gravity 10 1 instance 4 exposed
Issued
Aug 14, 2009
Abate by
Aug 27, 2009
Penalty
Initial $1,750 · Current $1,750
Recent events (2)
  • — F (S) $1750.00
  • — Z (S) $1750.00

1926.50 B

Serious Gravity 10 1 instance 4 exposed
Issued
Aug 14, 2009
Abate by
Aug 27, 2009
Penalty
Initial $1,750 · Current $1,750
Recent events (2)
  • — F (S) $1750.00
  • — Z (S) $1750.00

1926.50 C

Serious Gravity 10 1 instance 4 exposed
Issued
Aug 14, 2009
Abate by
Aug 27, 2009
Penalty
Initial $1,750 · Current $1,750
Recent events (2)
  • — F (S) $1750.00
  • — Z (S) $1750.00

1926.651 B03

Serious Gravity 10 1 instance 4 exposed
Issued
Aug 14, 2009
Abate by
Aug 27, 2009
Penalty
Initial $1,750 · Current $1,750
Recent events (2)
  • — F (S) $1750.00
  • — Z (S) $1750.00

1926.950 C01

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 14, 2009
Abate by
Aug 27, 2009
Penalty
Initial $1,750 · Current $1,750
Recent events (2)
  • — F (S) $1750.00
  • — Z (S) $1750.00

1926.951 A01 II

Serious Gravity 10 1 instance 4 exposed
Issued
Aug 14, 2009
Abate by
Aug 27, 2009
Penalty
Initial $1,750 · Current $1,750
Recent events (2)
  • — F (S) $1750.00
  • — Z (S) $1750.00

1926.951 A01 III

Serious Gravity 10 1 instance 4 exposed
Issued
Aug 14, 2009
Abate by
Aug 27, 2009
Penalty
Initial $1,750 · Current $1,750
Recent events (2)
  • — F (S) $1750.00
  • — Z (S) $1750.00

1926.951 D02

Serious Gravity 10 1 instance 4 exposed
Issued
Aug 14, 2009
Abate by
Aug 27, 2009
Penalty
Initial $1,750 · Current $1,750
Recent events (2)
  • — F (S) $1750.00
  • — Z (S) $1750.00

1926.95 A

Willful Gravity 10 1 instance 4 exposed
Issued
Aug 14, 2009
Abate by
Aug 27, 2009
Penalty
Initial $49,000 · Current $49,000
Recent events (2)
  • — F (W) $49000.00
  • — Z (W) $49000.00

1926.950 C01

Willful Gravity 10 1 instance 2 exposed
Issued
Aug 14, 2009
Abate by
Aug 27, 2009
Recent events (2)
  • — F (W)
  • — Z (W)

View Thedford Construction Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 312120215.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.