PUEBLO, CO —
OSHA Inspection: WASTE CONNECTIONS OF COLORADO INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WASTE CONNECTIONS OF COLORADO INC. in 28900 EAST STATE HIGHWAY 96, PUEBLO, CO 81002 (NAICS 562212). OSHA activity number 312134893.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WASTE CONNECTIONS OF COLORADO INC.
- Site address
- 28900 EAST STATE HIGHWAY 96
- City
- PUEBLO
- State
- CO
- ZIP
- 81002
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562212
- SIC code (legacy)
- 4953
- Employees
- 45
- Ownership type
- A
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Aug 18, 2008
- Abate by
- Sep 20, 2008
- Penalty
- Initial $1,275 · Current $890 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to injury from flying plastic projectiles from mechanical failure of the shop air system: (a) On or about August 7, 2008 and at times prior, employees were exposed to shrapnel injury while compressed air was utilized to operate machinery, without the proper piping system. Among other methods, the following are feasible and acceptable methods to minimize the probability of injury during the transfer of compressed air throughout the facility. 1. Follow American Society for Testing and Materials (ASTM) Standard D1785-86, which states polyvinyl chloride (PVC), pipes can be used for transportation of compressed air and gases only if the PVC pipes are made of shatter resistant material or are encased in a shatter resistant material. 2. Follow American National Standards Institute/American Society of Mechanical Engineers (ANSI/ASME) B31.8-198 Gas Transmission and Distribution Piping Systems Standard which limits the operating pressure of plastic piping distributions systems to 100 pounds per square inch (psi) and prohibits the installation of such systems above ground except where " the above ground portion of the plastic service line is completely enclosed in a conduit or casing of sufficient strength to provide protection from external damage and deterioration." 3. Replace all existing PVC pipes with a cast iron, or other type of approved type piping rated to transport compressed air safely above ground. Abatement Note: Abatement certification and documentation is required for this item (see enclosed "Sample Abatement-Certification Letter").
Recent events (2)
- — I (O) $890.00
- — Z (S) $1275.00
1910.134 C01
- Issued
- Aug 18, 2008
- Abate by
- Nov 10, 2008
- Penalty
- Initial $1,275 · Current $890 Reduced
Recent events (2)
- — I (O) $890.00
- — Z (S) $1275.00
1910.303 G01 III
- Issued
- Aug 18, 2008
- Abate by
- Sep 20, 2008
- Penalty
- Initial $1,275 · Current $890 Reduced
Recent events (2)
- — I (O) $890.00
- — Z (S) $1275.00
1910.304 B02
- Issued
- Aug 18, 2008
- Abate by
- Sep 20, 2008
- Penalty
- Initial $1,275 · Current $890 Reduced
Recent events (2)
- — I (O) $890.00
- — Z (S) $1275.00
1904.40 A
- Issued
- Aug 18, 2008
- Abate by
- Aug 22, 2008
Recent events (2)
- — I (O)
- — Z (O)
More inspections at Waste Connections of Colorado INC.
View Waste Connections of Colorado INC.'s full OSHA safety record →
More inspections in this industry (NAICS 562212)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 312134893.