Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: DEAN'S SAFETY CONSULTANTS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DEAN'S SAFETY CONSULTANTS in GOODMAN POINT #15, CORTEZ, CO 81321 (NAICS 213111). OSHA activity number 312135353.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dean'S Safety Consultants for free Get an email when a new federal OSHA severe-injury report for Dean'S Safety Consultants is published. One employer, no account, unsubscribe in one click.
Site address
GOODMAN POINT #15
City
CORTEZ
State
CO
ZIP
81321
Mailing
P.O. BOX 1227, CORTEZ, CO 81321
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213111
SIC code (legacy)
1381
Employees
2
Ownership type
Private (A)

1 citation on file for this inspection.

5(a)(1)

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Oct 16, 2008
Abate by
Oct 22, 2008
Penalty
Initial $1,500 · Current $1,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which was free from
recognized hazards which
were likely to cause death or serious physical harm from injury in that,
employees were exposed
to being asphyxiated from hydrogen sulfide in that, no hydrogen sulfide
evacuation drills had
been performed at this location:
a) On or about August 14, 2008 and at times prior, employees were exposed
to illness in that,
employees were exposed to being asphyxiated from hydrogen sulfide in that
no evacuation
hydrogen sulfide drills had been performed at this location.
Among other methods, one feasible and acceptable method to correct this
hazardous condition
would be to implement and perform an evacuation drill for hydrogen sulfide
which complies
with API RP49-10.7.
Abatement Note:  Abatement certification and documentation is required for
this item (see
enclosed "Sample Abatement-Certification Letter").
Recent events (2)
  • · I (S) $1500.00
  • · Z (S) $1500.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 312135353.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.