SOUTH FORK, CO ·
OSHA Inspection: HUSMANN PLUMBING
Unprogrammed Related inspection · Health discipline
At a glance
On , OSHA opened an unprogrammed Related health inspection of HUSMANN PLUMBING in 055 IRON BRIDGE PLACE, SOUTH FORK, CO 81554 (NAICS 238220). OSHA activity number 312137649.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HUSMANN PLUMBING
- Site address
- 055 IRON BRIDGE PLACE
- City
- SOUTH FORK
- State
- CO
- ZIP
- 81554
- Mailing
- 18 CONEJOS AVENUE, ALAMOSA, CO 81101
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- SIC code (legacy)
- 1711
- Employees
- 12
- Ownership type
- A
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 10, 2009
- Abate by
- May 5, 2009
- Penalty
- Initial $2,100 · Current $2,100
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that, employees were exposed to injuries from an explosion and fire hazards: a) On or about November 24, 2008, the employer as the creating/exposing contractor did not protect employees/workers from explosion and fire hazards in that; 1) The piping outlets to the first floor fire places were not capped or plugged until connected to the appliances. 2) The L.P. piping system was not inspected and tested prior to pressuring the system. 3) Ignition sources were not controlled during the pressurizing of the L.P. system. Among other methods, one feasible and acceptable abatement method to correct this hazardous condition would be to inspect all gas piping and appliances in accordance with NFPA section 54, and the International Fuel Gas Code. Abatement Verification: Abatement certification and documentation is required for this item (see enclosed "Sample Abatement-Certification Letter").-Certification
1926.21 B05
- Issued
- Apr 10, 2009
- Abate by
- May 5, 2009
- Penalty
- Initial $2,100 · Current $2,100
1926.21 B06 I
- Issued
- Apr 10, 2009
- Abate by
- May 5, 2009
1910.1200 E02 II
- Issued
- Apr 10, 2009
- Abate by
- May 5, 2009
- Penalty
- Initial $2,100 · Current $2,100
More inspections at Husmann Plumbing
View Husmann Plumbing's full OSHA safety record →
More inspections in this industry (NAICS 238220)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 312137649.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.