BELLE GLADE, FL —
OSHA Inspection: RECYCLING MIAMI, INC. D/B/A RECYCLING METALS
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of RECYCLING MIAMI, INC. D/B/A RECYCLING METALS in 2308 CYPRESS LANE, BELLE GLADE, FL 33430 (NAICS 423930). OSHA activity number 312147663.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RECYCLING MIAMI, INC. D/B/A RECYCLING METALS
- Site address
- 2308 CYPRESS LANE
- City
- BELLE GLADE
- State
- FL
- ZIP
- 33430
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- SIC code (legacy)
- 5093
- Employees
- 16
- Ownership type
- A
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 30, 2008
- Abate by
- Oct 6, 2008
- Penalty
- Initial $750 · Current $563 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a) On or about 7/8/08, an employee was injured when he cut open a compressed gas oxygen cylinder with a chop saw without first emptying the contents and purging the cylinder. Among other methods, one feasible and acceptable method to correct this hazard is to follow Section 7.5.4 of CGA P-22-2007 (publication 22 of the Compressed Gas Association, Inc.), a consensus standard which states that the cylinder contents must be removed and the cylinder purged with an inert gas prior to cutting.
Recent events (2)
- — I (S) $563.00
- — Z (S) $750.00
1910.212 A05
- Issued
- Sep 30, 2008
- Abate by
- Oct 3, 2008
- Penalty
- Initial $450 · Current $337 Reduced
Recent events (2)
- — I (S) $337.00
- — Z (S) $450.00
1910.304 F05 IVB
- Issued
- Sep 30, 2008
- Abate by
- Oct 27, 2008
- Penalty
- Initial $600 · Current $450 Reduced
Recent events (2)
- — I (S) $450.00
- — Z (S) $600.00
1910.1200 E01
- Issued
- Sep 30, 2008
- Abate by
- Oct 27, 2008
Recent events (2)
- — I (O)
- — Z (O)
More inspections in this industry (NAICS 423930)