GALENA PARK, TX —
OSHA Inspection: MAGELLAN MIDSTREAM PARTNERS
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MAGELLAN MIDSTREAM PARTNERS in 12904 AMERICAN PETROLEUM ROAD, GALENA PARK, TX 77029 (NAICS 424710). OSHA activity number 312155443.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAGELLAN MIDSTREAM PARTNERS
- Site address
- 12904 AMERICAN PETROLEUM ROAD
- City
- GALENA PARK
- State
- TX
- ZIP
- 77029
- Mailing
- P.O. BOX 52, GALENA PARK, TX 77547
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424710
- SIC code (legacy)
- 5171
- Employees
- 72
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Jul 23, 2008
- Abate by
- Jul 27, 2008
- Penalty
- Initial $5,000
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish to each of his employees a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being struck by hooks, swaged wire rope sockets and thimbles attached to mooring lines at Dock #1. Dock #1; a mooring line constructed of wire rope utilized to moor MV Sea Trout was not inspected by a competent person capable of recognizing obvious and existing rust corrosion. This condition exposed employees to a struck-by hazard. Among other methods, feasible and acceptable abatement to correct this hazard is to train wire rope inspectors in the recognition of wire rope damage such as but not limited to corrosion, kinks, heat damage and peening. Implement electromagnetic non-destructive testing of wire rope, perform field lubrication and remove damaged wire rope from service or replace it accordingly. To retard corrosive deterioration, the wire rope should be kept well lubricated and in situations where extreme corrosive action can occur, it may be necessary to use galvanized wire rope. DISCLAIMER: You are not limited to the abatement methods suggested above. The methods explained are general and may not be effective in all cases. The employer is responsible for selecting and carrying out an appropriate method.iate
Recent events (2)
- — R (S)
- — Z (S) $5000.00
More inspections at Magellan Midstream Partners
View Magellan Midstream Partners's full OSHA safety record →
More inspections in this industry (NAICS 424710)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 312155443.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.