PYOTE, TX —
OSHA Inspection: KEY ENERGY SERVICES, INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of KEY ENERGY SERVICES, INC in RIG 298, UNIVERSITY 18-46A #2H, PYOTE, TX 79777 (NAICS 213111). OSHA activity number 312238827.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KEY ENERGY SERVICES, INC
- Site address
- RIG 298, UNIVERSITY 18-46A #2H
- City
- PYOTE
- State
- TX
- ZIP
- 79777
- Mailing
- 2407 E MURPHY, ODESSA, TX 79761
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213111
- SIC code (legacy)
- 1381
- Employees
- 8542
- Ownership type
- A
Citations
7 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 23, 2009
- Abate by
- Jan 28, 2009
- Penalty
- Initial $1,083 · Current $1,083
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the condition(s) listed below: Key Energy Services, Rig 298, University 18-41A #2H, Ward County, TX. For the period of time up to and including 08/13/08, the emergency escape line did not have flagging material or any other means to make the line more visible. American Petroleum Institute states in Recommended Practice for Use and Procedures for Inspection, Maintenance, and Repair of Drilling and Well Servicing Structures, API Recommended Practice 4G, Third Edition, April 2004, Section 14.5, paragraph f, "The rig contractor shall be responsible for placing a visible marker on each guywire." Feasible and acceptable abatement methods would include ensuring all emergency escape lines and guywires are flagged with a visible material.
Recent events (2)
- — J (S) $1083.00
- — Z (S) $1083.00
5(a)(1)
- Issued
- Jan 23, 2009
- Abate by
- Mar 12, 2009
- Penalty
- Initial $1,275 · Current $1,275
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the condition(s) listed below: Key Energy Services, Rig 298, University 18-41A #2H, Ward County, TX. For the period of time up to and including 08/13/08, the employer did not ensure that the stairways used by employees for access to and from the rig floor, mud pits, and mud room had handrails and midrails extending the entire length of the stairways. American Petroleum Institute states in Recommended Practice for Occupational Safety for Oil and Gas Well Drilling and Servicing Operations, API Recommended Practice 54, Third Edition, August 1999, Reaffirmed March 2007, states in paragraph 9.3.8 "All open stairways of four (4) or more risers shall be securely fastened and equipped with handrails and midrails extending the entire length of the stairway." Feasible and acceptable methods of abatement include ensuring all handrails and midrails extend the entire length of the stairway.
Recent events (2)
- — J (S) $1275.00
- — Z (S) $1275.00
1910.304 G05
- Issued
- Jan 23, 2009
- Abate by
- Feb 4, 2009
- Penalty
- Initial $1,275 · Current $1,275
Recent events (2)
- — J (S) $1275.00
- — Z (S) $1275.00
1910.305 G01IV
- Issued
- Jan 23, 2009
- Abate by
- Feb 4, 2009
- Penalty
- Initial $1,275 · Current $1,275
Recent events (2)
- — J (S) $1275.00
- — Z (S) $1275.00
1910.305 G02II
- Issued
- Jan 23, 2009
- Abate by
- Feb 4, 2009
Recent events (2)
- — J (S)
- — Z (S)
1910.305 G02II
- Issued
- Jan 23, 2009
- Abate by
- Feb 4, 2009
- Penalty
- Current $1,275
Recent events (2)
- — J (S) $1275.00
- — Z (S)
1910.23 C01
- Issued
- Jan 23, 2009
- Abate by
- Feb 4, 2009
- Penalty
- Initial $7,500 · Current $4,500 Reduced
Recent events (2)
- — J (R) $4500.00
- — Z (R) $7500.00
More inspections at KEY Energy Services, INC
View KEY Energy Services, INC's full OSHA safety record →
More inspections in this industry (NAICS 213111)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 312238827.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.