STATESVILLE, NC —
OSHA Inspection: ULTRACLEAR COATINGS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ULTRACLEAR COATINGS, INC. in 2226 SPEEDBALL ROAD, STATESVILLE, NC 28677 (NAICS 325998). OSHA activity number 312243918.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ULTRACLEAR COATINGS, INC.
- Site address
- 2226 SPEEDBALL ROAD
- City
- STATESVILLE
- State
- NC
- ZIP
- 28677
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325998
- SIC code (legacy)
- 2819
- Employees
- 4
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
2 citations on file for this inspection.
95012901
- Issued
- Jun 26, 2008
- Abate by
- Jul 7, 2008
- Penalty
- Initial $250 · Current $250
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish to each of his employees conditions of employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm in that employees were exposed to struck-by hazards: a)production area, for the industrial steel storage racks used to store palletized material, no front to back supports were used to prevent pallets from falling between the beams. Among other methods, feasible and acceptable abatement methods include: 1. Install a rack decking system with a rated load capacity equal to or greater than the load rating of the rack beams. 2. Follow the guidelines established in the American National Standards Institute (ANSI) MH 16.1-2004, Section 1 Paragraph 1.4.1, (4) Ensure that pallets are properly placed onto pallet load support members in a properly stacked and stable position.
1910.303 G01 II
- Issued
- Jun 26, 2008
- Abate by
- Jul 7, 2008
More inspections in this industry (NAICS 325998)
More inspections in NC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 312243918.