Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WESTERN BUILDING GROUP

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WESTERN BUILDING GROUP in 12300 LAS VEGAS BLVD., SOUTH, LAS VEGAS, NV 89044 (NAICS 238990). OSHA activity number 312282601.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Western Building Group — free Get an email when a new federal OSHA severe-injury report for Western Building Group is published. One employer, no account, unsubscribe in one click.
Site address
12300 LAS VEGAS BLVD., SOUTH
City
LAS VEGAS
State
NV
ZIP
89044
Mailing
1054 CENTRAL INDUSTRIAL DRIVE, SAINT LOUIS, MO 63110
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
SIC code (legacy)
1799
Employees
12
Ownership type
A
Industry flags
Construction safety.

1 citation on file for this inspection.

618037501

Serious Gravity 01 1 instance 1 exposed
Issued
Feb 5, 2009
Abate by
Feb 10, 2009
Penalty
Initial $225 · Current $225
Nevada Revised Statute 618.375(1):  Duties of employers.  The employer
failed to furnish
employment and a place of employment which was free from recognized
hazards that were
causing or likely to cause death or serious physical harm to his employees:
The employer failed to protect employees, as follows:
a.At the M Resort construction project, 12300 Las Vegas Boulevard South,
Las
Vegas, NV.  An employee on the scissor lift was installing zinc flashing,
this
employee was elevated more than 15 feet with the chain dangling on the
side and
not secured for the equivalent structure used in place of mid-rails.  The
employee
was exposed to possible serious injuries or death from potential fall
hazard of
more than 15 feet in elevation.
Reference:  ANSI/SIA A92.6-1990, Self Propelled Elevating Work Platform.
Para 4.12.2.2 Mid-Rail. the guardrail system shall include a mid-rail
approximately midway  between the top rail and the platform surface.
Equivalent
structure may be used in place of mid-rails, but shall meet the strength
requirements described in 4.12.2.4.
One feasible and acceptable abatement is to ensure that employees follow
all
safety rules on the proper operation of scissor lifts.r

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 312282601.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.