JACKSON SUMMIT, PA ·
OSHA Inspection: TITAN WIRELINE SERVICES INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TITAN WIRELINE SERVICES INC in BECKER 4041H,WARNER RD., JACKSON SUMMIT, PA 16936 (NAICS 213112). OSHA activity number 312293889.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TITAN WIRELINE SERVICES INC
- Site address
- BECKER 4041H,WARNER RD.
- City
- JACKSON SUMMIT
- State
- PA
- ZIP
- 16936
- Mailing
- P.O.BOX 286, ELDERTON, PA 15736
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- SIC code (legacy)
- 1389
- Employees
- 5
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Mar 17, 2010
- Abate by
- Mar 22, 2010
- Penalty
- Initial $2,100
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that, employees were exposed to struck-by hazards from unsecured well head connections: a) East Resources Becker 404 1H Gas Well/Tioga County/Jackson Twp.PA: Employees positioned too close to the well head during hydraulic fracking operations were exposed to struck-by hazards from a failed chixsen or elbow connecting long iron from the manifold trailer to the well head, on or about 11/06/09. Among other methods, one feasible and acceptable method to abate this hazard is to ensure wire line units are spotted as far away from fracturing units as practicable in accordance with American Petroleum Institute (API) RP 54 Recommended Practice for Occupational Safety of Oil and Gas Well Drilling and Servicing Operations Manual, page 24, section 13.2.1. ABATEMENT OBSERVED NO CERTIFICATION REQUIRED